Technical article 104835

After upgrading to OpenServer Release 5, my application will not execute.

OpenServer 5.0.0

Written · Last revised

Problem

I have just upgraded my system to SCO OpenServer Release 5.0.0.

SCO NOTE:  In the example cited, the application is Lotus'
           Lotus 1-2-3 for SCO UNIX Version 1.1.  However,
           this issue could apply to any application,
           commercial or in-house, that relies on the
           output of the uname(C) command.

I have a licensed copy of Lotus 1-2-3 that was installed on a previous release of the operating system.

-- or --

I installed Lotus 1-2-3 for SCO UNIX on SCO OpenServer Release 5.0.0 and it now appears as an installed product in the SCOAdmin Software Manager.

When I invoke Lotus 1-2-3, using one of the authorized user accounts, I see an error message similar to the following:

123: Host name does not match license
Why can I no longer execute Lotus 1-2-3?

Cause

Lotus 1-2-3 will not execute under SCO OpenServer Release
5.0.0 because Lotus 1-2-3 fails the licensing check.  A change
was made, in SCO OpenServer Release 5.0.0, which was mandated
for POSIX conformance, after Lotus 1-2-3 was released.

Solution

To allow Lotus 1-2-3 to successfully execute on your SCO OpenServer Release 5.0.0, you will need to complete the following procedure:

1. Log into your system as root.

2. Run "uname -n" and obtain the value for your nodename.

3. Edit the file:
/etc/conf/pack.d/kernel/space.c

And change the line, (about line 62) that reads:

#define OPSYS "SCO_SV"

so that it contains your node name:

#define OPSYS "mynode"

where "mynode" was obtained in step 2.

4. Relink a new kernel and reboot.

Lotus 1-2-3 should now pass the licensing check and start successfully.

From the Xinuos technical article database, record 104835. Reproduced with permission. The original is at www.sco.com/ta/104835, which is reachable but blocked from search engines. Xinuos marks this article against a retired product line. That refers to the product’s lifecycle, not to whether the advice still works — plenty of it still applies to running systems.

Next step

Need this fixed rather than explained?

Tell us the release, what the system runs and what it is doing. We will reply by email with what we would do next.

  • You deal with the people who do the work
  • No obligation, and no upgrade required before we will help
  • We tell you plainly if something is not worth doing

Send an enquiry