Problem
When I set my system date to the year 2000 or beyond, the SCOadmin Backup manager fails. In both the GUI and charm interface, the Backup manager window appears for a few seconds and then disappears.
An error message similar to the following may be displayed:
Uncaught error in Tcl program: backupGUI: Unable to convert date-time string "00:00" while executing "convertclock 00:00" invoked from within "set todaysDate [convertclock 00:00].." (procedure "RefreshMainForm" line 3)...
Cause
The vtcl(TCL) convertclock command cannot process dates in the year 2000 and beyond correctly.
Solution
If you are using SCO OpenServer Release 5.0.0 or SCO Internet FastStart Release 1.0.0, SCO recommends that you upgrade to SCO OpenServer Release 5.0.5. For more information about upgrades, see:
http://www.sco.com/upgradeIf you are using SCO OpenServer Release 5.0.2 or 5.0.4, SCO Internet FastStart Release 1.1.0 or SCO OpenServer Internet FastStart Release 5.0.4, then you should apply Support Level Supplement (SLS) OSS601A to your system to resolve this problem.
This problem does not exist in SCO OpenServer Release 5.0.5.
See also