Corollary system gets "WARNING: IP:spinning on PCB Fxxxxxxx" messages.

OpenServer 5.0.0

Written · Last revised

Problem

I am running SCO OpenServer Release 5.0.0 with SCO SMP (Symmetrical Multiprocessing) Release 5.0.0 on a Corollary Architecture machine and the following message is displayed on the console:

WARNING: IP:spinning on PCB:<address>

This only happens on systems where networking is in use.

Cause

A fault was found in the SCO OpenServer Release 5.0.0 Corollary SMP driver that resulted in a process waiting on a lock that was never released.

Solution

This problem has been addressed by SLS OSS449F.  Please refer to                 Technical Article 107704 for details.

From the Xinuos technical article database, record 104995. Reproduced with permission. The original is at www.sco.com/ta/104995, which is reachable but blocked from search engines. Xinuos marks this article against a retired product line. That refers to the product’s lifecycle, not to whether the advice still works — plenty of it still applies to running systems.

Next step

Need this fixed rather than explained?

Tell us the release, what the system runs and what it is doing. We will reply by email with what we would do next.

  • You deal with the people who do the work
  • No obligation, and no upgrade required before we will help
  • We tell you plainly if something is not worth doing