Problem
I need to be able to access my NetWare servers using the SCO
Gateway for NetWare. How do I configure this? Solution
Before you start to configure the SCO Gateway for NetWare, you will need to know two pieces of information from the NetWare server:
(1) The network number, which is an 8 digit hex number.
(2) The frame type. This is most often 802.3 or 802.3 with
802.2 headers, also known as 802.2.You can get this information from the NetWare server by typing "config" on the NetWare console. Additionally you could find this information in your AUTOEXEC.NCF file.
Here is an example of the output:
SLOVELL:config File server name: SLOVELL IPX internal network number: 98765432
SMC EtherCard PLUS Server Driver v4.16 (930503)
Version 4.16 May 3, 1993
Hardware setting: I/O Port 280h to 29Fh, Memory C8000h
to CBFFFh, Interrupt FhNode address: 0000C034194D Frame type: ETHERNET_802.3 Board name: SMCIPX LAN protocol: IPX network 0000FEED
The pertinent lines are the "LAN protocol" line and the "Frame type" line.
The LAN protocol is IPX which is what the SCO Gateway will use
to connect to the NetWare server. The network number is
0000FEED.The Frame type is 802.3.You are now ready to configure the SCO Gateway for NetWare.
If you haven't already added the IPX protocol you must do that
first. If you have, you should verify that the Network Number
and framing type are correct.To add the IPX protocol, run netconfig(ADM). Highlight the
adapter and choose Add Protocol from the Protocol menu.Choose the IPX protocol. You will be prompted for the
following information:Maximum Number of NVT LoginsThis parameter will not affect the SCO Gateway for
NetWare. This can be left at the default value unless
you will be using a large number of DOS NVT clients.Internal Network NumberNote that the "Internal Network Number" is not the
same as the Network Number. The Internal Network
Number should be unique for each NetWare and SCO
server on the network.Network NumberThe Network Number is the IPX network number from the
LAN protocol line on the NetWare console. In our
example, we would enter 0000FEED.Framing TypeIn our example, we would use 802.3 for the framing type.
After the IPX configuration is complete, you can add the SCO
Gateway for NetWare. This is done in netconfig(ADM).
Highlight the IPX stack and choose Add Protocol from the
Protocol menu. If you don't see Gateway for NetWare as an
option here, you may need to install it from the install media.
See TA101293 "How do I install Gateway for NetWare".When you exit the Network Configuration Manager, you will be
prompted to relink the kernel. The kernel must be relinked
for your changes to take effect. You also must allow the
kernel environment to be rebuilt. After the link is completed
you will need to reboot.After rebooting, the Gateway will be active. You should be
able to see the NetWare File Servers on your network by
typing:slistIf this fails to give you the list, or returns an error
message, you have probably configured the IPX protocol
incorrectly. Check to ensure that you have the correct
Network Number and Frame Type. Note that the default Frame
type, "802.3 with 802.2 headers", is not the same as 802.3,
which is commonly used on NetWare Servers. See also
"SCO OpenServer Guide to Gateways for LAN Servers: Troubleshooting SCO Gateway for NetWare"
TA101293 "How do I install Gateway for Netware"