Technical article 118146

How do I connect my NT server to an Openserver system using PPP?

OpenServer 5.0.5OpenServer 5.0.6

Written

Problem

I have a Microsoft NT 4.0 server working on a remote site and would like to be able to connect to an Openserver system using PPP.

Solution

By using the "RAS" dialup utility that Microsoft offers on NT, it is possible to automate a ppp dialup session to an SCO Openserver system.

An example configuration using Morning Star PPP follows.

This technical article assumes that the remote Openserver system already has the "Morning Star PPP" software installed and configured. You may wish to refer to the end of this technical article for help if the PPP software is not set up on the Openserver server.

There are many different options available during wizard
installations.  This example only mentions those that need to be
changed from default, or checked.

On the NT server, logon as the administrator.

The first task is to check and/or add the "RAS" software.  This is
Microsoft's "Remote Access Software".  To check this;

1. Right-click Network Neighborhood, and then click "Properties".

2. Click the "Services" tab, and look for "Remote Access Service"
   If this is not listed, click on "Add".  If it is listed, skip
   to the next section.
3. Click "Remote Access Service", and then click OK.  Insert
   the source CD-ROM if you are prompted to do so.

4. Click "Close", and then restart the computer when you are prompted to do so.

The next task is to install the modem.  Check that the modem is
physically connected, then:

1. Click on "Start", "settings", "control panel".

2. Click on "Modems", if this is not blank, skip to the next section.

3. Click on "Add".  This will start the add modem wizard.  Click
   "next".
The wizard will examine all ports and find the modem.  If no modem
is detected, check the modem and connections, or install additional
drivers that were supplied with the modem.  Check the modem vendors
installation details.
          4. When the modem is found, it will be highlighted in a list.  Click
	     "finish", the modem will be installed.  The system may need be
             rebooted.

Now the modem needs to be linked the "RAS" utility.

1. After locating the modem, the "RAS" manager window may appear. If this does not happen, or the system has been rebooted, Right-click Network Neighborhood, and then click Properties. Click the "Services" tab, and then double click on the Remote Access Service.

2. If the modem is not already listed, then click on add.  This will
   start an "add RAS wizard".  Select the modem listed, and then
   click OK.

3. The modem should now be listed in the "ras" manager window. Click on "Configure" and ensure that it is set to allow "Dial out" Click "Network" and ensure that only "tcp/ip" has a tick next to it.

"Click" continue.  The "ras" manager window will disappear.

Next a logon script will need to be created.

1. Use an editor, e.g.; notepad.
2. Insert the following lines;
proc main
        delay 2
        transmit "^M^M"
        delay 2
        transmit $USERID
        transmit "^M"
        delay 5
        transmit $PASSWORD
        transmit "^M"
        delay 3
        transmit "ppp^M"
        done:
endproc
3. Save this as "c:\winnt\system32\ras\<script name>.scp"

Next setup the dial out connection details.

1. Double click "My Computer", then double click "Dial up networking"

2. Click "New" and then type in a name for this connection, then click "Next".

3. Select "I'm calling the internet" and "Send my plain text password" options and then "Next".

4. Enter the phone number for this connection.

5. Click "Next" to finish.  Ensure that the connnection that has just
   been added is highlighted and then click "more", Edit entry and
   modem properties.
6. Click on the "Server" tab and ensure that only tcp/ip is selected.
   "Enable software compression" and "PPP LCP extensions" should also
   be selected.  Click "tcp settings" and ensure that "IP" and "Name
   Server" options are set to "server assigned".  "Use IP Header
   compression" and "Use default gateway" should have a tick next to
   them. Click "OK".
          7. Click on the "Script" tab, and select "Run this script".  Click the
	     down arrow and select the script that was saved in the last
             section.  Click "OK".
8. Test the connection.  Click on "Dial".  A window should appear,
   enter the ppp login on the Openserver system.  The default is nppp.
   Enter the password for the nppp account on the remote server.  The
   "Domain" box may be ignored unless the Openserver system has AFPS
   installed.  You may wish to type in the name of that NT/AFPS
   domain.
9. When the modem has established connection, a message window should
   appear that says "authenticating", and then if the login details
   are correct, "Registering the computer on the network".  A larger
   window that says the systems are connected should then appear.
10. Ping the IP address of the remote Openserver system to confirm
    that the networking is working properly.  If the remote system has
    been setup correctly, the nameserver address should also have been
    assigned.  This can be checked by clicking on "start", then run.
    Enter "cmd" and then click "OK".  An MSDOS type window should
    appear.  "cd" into \winnt\system32 and then enter "ipconfig /all".
    This will show all the networking settings, the ppp interface is
    listed at the bottom.
11. A "RAS Monitor" icon will appear in the systray (next to the
    clock, usually at the bottom right hand corner), upon successful
    connection.  To drop the line, double click on the icon and then
    click on "Hang up".

See also

ta105345, "How to manually configure Morning Star PPP for incoming/ outgoing connections."

From the Xinuos technical article database, record 118146. Reproduced with permission. The original is at www.sco.com/ta/118146, which is reachable but blocked from search engines.

Next step

Need this fixed rather than explained?

Tell us the release, what the system runs and what it is doing. We will reply by email with what we would do next.

  • You deal with the people who do the work
  • No obligation, and no upgrade required before we will help
  • We tell you plainly if something is not worth doing

Send an enquiry