Technical article 110746

How do I install SLS APP336C on my SCO OpenServer 5 system running FoxBASE+?

OpenServer 5.0.0OpenServer 5.0.2OpenServer 5.0.4OpenServer 5.0.5

Written · Last revised

Problem

I have one of the following problems with regard to Support Level Supplement (SLS) APP336C on my SCO OpenServer 5 system running FoxBase+:

1. I am not able to install SLS APP336C on my SCO OpenServer 5 system.

2. I am not able to reapply APP336C and do not see an /etc/perms/foxsls+ file to remove.

3. I thought that I had applied APP336C successfully but I am still having problems that APP336C is supposed to correct.

Cause

ta109503, "What is the SCO FoxBASE+ Support Level Supplement (SLS)
APP336C?", describes the procedure to install APP336C on SCO UNIX
System V/386 Release 3.2 Operating System Version 4.2, SCO Open
Desktop Release 3.0 or SCO Open Server Release 3.0. However, the
custom command will not work as documented for SCO OpenServer 5
systems.

Solution

Below are the modified steps for installing SLS APP336C on SCO OpenServer 5 operating systems.

IMPORTANT NOTE: SCO does not support or warrant any FoxBASE product on SCO OpenServer 5.

Note: If you have installed this SLS before, issue the command:

# rm /etc/perms/foxsls+

This will remove any past reference to the SLS.

1. Download SLS APP336C to an SCO OpenServer 5 machine, making sure you specify a binary file transfer, if needed.

The checksum/size of the app336c file should be:

# sum -r app336c
17719  2880 app336c

2. Copy the SLS to a floppy diskette using the 'dd' command. This can be accomplished with the command:

dd if=app336c of=/dev/install bs=18k

The "of=/dev/install" should be your default floppy device; otherwise, insert the correct device node for your system. Examples for a 3.5 inch floppy would be /dev/rfd0135ds18 or /dev/rfd1135ds18.

(At this point, a sum -r on /dev/install or /dev/rfd0135ds18 should also match the sum mentioned above.)

3. Install the SLS using "custom" or Software Manager in either the GUI or Character mode. (Note that custom -m by itself does not work.)

4. Choose to install the product and follow the instructions on the screen. Use the "Activation Key" card that you received with your original purchase of FoxBASE+ Runtime and/or Development System versions to brand and enable the new versions of the FoxBASE+ binaries to be executed.

5. During installation a dialog box will appear stating that verification errors have been found. Press continue and proceed with the install.

Note that if you choose "Details," the following error line will be repeated:

Unable to determine user id value for user "uid_1003" on file "./tmp/app336c/<filename>", using default uid of 2

where <filename> will be foxpcomp.pr, foxplus.pr, foxrun.pr, foxplus.rsc, and foxphelp.hlp.

6. Installation of SLS APP336C is now complete. However, if you have not yet followed the instruction in ta110515, "I have installed SLS APP336C but SCO FoxBASE+ still doesn't recognize year 2000 as a leap year," you must do so in order for FoxBASE+ to recognize the year 2000 as a leap year.

If you need to remove or reapply APP336C, just go into custom or the Software Manager and take the appropriate steps to remove the patch just as you would any other patch. In extreme cases, you might need to remove the file app336c in /etc/perms to reapply the patch, but normally you will not need to.

NOTES:    SCO does not support or warrant any FoxBASE product on SCO
          OpenServer 5.

It is important that you follow ta110515 in order to have FoxBASE+ recognize the year 2000 as a leap year.

See also

ta109503, "What is the SCO FoxBASE+ Support Level Supplement (SLS) APP336C?"

ta109923, "What is contained in SLS UOD426D, the Year 2000 SLS for SCO UNIX and Open Desktop?"

ta110515, "I have installed SLS APP336C but SCO FoxBASE+ still doesn't recognize year 2000 as a leap year."

From the Xinuos technical article database, record 110746. Reproduced with permission. The original is at www.sco.com/ta/110746, which is reachable but blocked from search engines. Xinuos marks this article against a retired product line. That refers to the product’s lifecycle, not to whether the advice still works — plenty of it still applies to running systems.

Next step

Need this fixed rather than explained?

Tell us the release, what the system runs and what it is doing. We will reply by email with what we would do next.

  • You deal with the people who do the work
  • No obligation, and no upgrade required before we will help
  • We tell you plainly if something is not worth doing

Send an enquiry