Problem
I am trying to run the Event Viewer utility on my Microsoft Windows NT 4.0 workstation to monitor events on my SCO AFPS primary domain controller (PDC). However, when I select the computer to view, I get the message:
Access is Denied. Cause
The NT workstation PC has not been logged onto the AFPS domain.
Solution
In order to log on to the AFPS domain, a user requires a user account in that domain. This has been previously set up on the domain primary domain controller (PDC). For Windows NT 4.0 workstations, if a correct domain logon is not done at system startup time, the workstation must be added to the AFPS domain later, and it will default to its local domain or workgroup.
On system startup, the Windows NT 4.0 workstation presents the user
with the option to enter a username, password, and domain. The
option to log on to a domain must have previously been configured
on the system via the "Control Panel", "Network", "Identification"
options. The other default option is to log on to the Workgroup.At this stage, a user can log on to a domain, but that domain may in fact only be its local domain, that is, it is the only member. The user must log on to the same domain as the AFPS (or NT) server.
If users only log on to their local domain, they can at a later point log on to the AFPS domain by adding themselves to that domain via the NT Server Tools Server Manager utility. Start the utility and select a domain, highlight the name of the computer (in general the PDC of the AFPS domain, although it may be a backup controller), and select "Add to domain".
If, at a later point, the workstation removes itself from the domain using the "Remove from Domain" option, this message is seen:
Removing <W/S Name> from the domain will render it incapable of authenticating domain logins until it is added to another domain.
This could be confusing by implying a workstation will allow remote logins to itself (that is, the machine) but it is in fact acting as a check on other workstations starting a login or session to the overall domain. It participates in domain security.
The Windows NT 4.0 workstation will contain a local version of the NT Server Tools. However, to view a server, with for example the "User Manager" or "Event Viewer", a server version of these utilities must must be loaded onto the workstation. These can be loaded from the AFPS server share. See the AFPS documentation for details.
See also
SCO Advanced File and Print Server System Guide, "Adding or removing domain computers", page 144, 145.
SCO Advanced File and Print Server Administrator's Handbook, "Installing administrative tools on clients", page 57.