Problem
On my SCO OpenServer system configured with Compaq Insight Management Agents, an error message similar to the following appears on the console and in the /usr/adm/messages file:
"NOTICE: ida0: slot 1: Invalid request on dev 135/0 blk 0 logical unit=0, block=0, size=1, cmd=0x66, status=0x10"
Cause
The "cmd=0x66" entry indicates that the disk array agent from
Insight Agents Version 3.82b issued an IDA_SENSE_SUBSYS_INFO
command to the array controller. SMART Array, SMART-2/P,
and SMART-2/E Controllers do not implement this command, which
results in the error message. Solution
This problem is corrected in version 3.82c of Compaq Insight Management Agents for SCO OpenServer 5, which is available from Compaq as SoftPaq SP6097.
This SoftPaq may be downloaded from Compaq at:
https://www.hpe.comNOTES: SMART-2DH, SMART-2SL, Smart 3100ES, and Smart 3200 Array
Controllers support the IDA_SENSE_SUBSYS_INFO command, so
they do not experience this problem.