Technical article 110627

I get an "Invalid request on dev 135/0 blk" message on a Compaq server with OpenServer installed.

OpenServer 5.0.0OpenServer 5.0.2OpenServer 5.0.4OpenServer 5.0.5

Written · Last revised

Problem

On my SCO OpenServer system configured with Compaq Insight Management Agents, an error message similar to the following appears on the console and in the /usr/adm/messages file:

"NOTICE: ida0: slot 1: Invalid request on dev 135/0 blk 0 logical unit=0, block=0, size=1, cmd=0x66, status=0x10"

Cause

The "cmd=0x66" entry indicates that the disk array agent from
Insight Agents Version 3.82b issued an IDA_SENSE_SUBSYS_INFO
command to the array controller.  SMART Array, SMART-2/P,
and SMART-2/E Controllers do not implement this command, which
results in the error message.

Solution

This problem is corrected in version 3.82c of Compaq Insight Management Agents for SCO OpenServer 5, which is available from Compaq as SoftPaq SP6097.

This SoftPaq may be downloaded from Compaq at:

https://www.hpe.com
NOTES:    SMART-2DH, SMART-2SL, Smart 3100ES, and Smart 3200 Array
          Controllers support the IDA_SENSE_SUBSYS_INFO command, so
          they do not experience this problem.

From the Xinuos technical article database, record 110627. Reproduced with permission. The original is at www.sco.com/ta/110627, which is reachable but blocked from search engines. Xinuos marks this article against a retired product line. That refers to the product’s lifecycle, not to whether the advice still works — plenty of it still applies to running systems.

Next step

Need this fixed rather than explained?

Tell us the release, what the system runs and what it is doing. We will reply by email with what we would do next.

  • You deal with the people who do the work
  • No obligation, and no upgrade required before we will help
  • We tell you plainly if something is not worth doing

Send an enquiry

We reply by email. If a server is down, say so in the first line. You can also write to help@scoexpert.com.