Technical article 110657

I get the error "The custom+ binary (backend) process has died" while trying to install SLS OSS601A.

OpenServer 5.0.0OpenServer 5.0.2OpenServer 5.0.4OpenServer 5.0.5

Written · Last revised

Problem

I am attempting to install Support Level Supplement (SLS) OSS601A on my SCO OpenServer system using the Software Manager. During the installation, the Software Manager fails with this error message:

The custom+ binary (backend) process has died.

If I look at the details of the error message it says:

Message id "INSTALL_ALREADY_NOT_APPLIED_PATCH" not in the current context

Cause

You are not installing SLS OSS601A according to the instructions in the cover letter that accompanies the SLS.

SLS OSS601A consists of two separate components:

OSS601A Software Manager patch for OpenServer 5.0.4 ONLY (ver oss601a.SoftMgr101)

Year 2000 Supplement for SCO OpenServer 5.0.2 and 5.0.4 (ver oss601a)

The above error message will appear:
-  if you attempt to install the Year 2000 component of SLS
OSS601A before the Software Manager patch.
- OR -
-  having installed the Software Manager patch, if you fail to
restart the Software Manager before proceeding on to install
the Year 2000 component of OSS601A.

Solution

Make sure you:

1. Install the Software Manager component of OSS601A first.

2. Exit and restart the Software Manager before continuing to install the Year 2000 Supplement component of OSS601A.

See also

ta110077, "What is addressed by SLS OSS601A, the Year 2000 Supplement for SCO OpenServer 5.0.2 and 5.0.4?"

From the Xinuos technical article database, record 110657. Reproduced with permission. The original is at www.sco.com/ta/110657, which is reachable but blocked from search engines. Xinuos marks this article against a retired product line. That refers to the product’s lifecycle, not to whether the advice still works — plenty of it still applies to running systems.

Next step

Need this fixed rather than explained?

Tell us the release, what the system runs and what it is doing. We will reply by email with what we would do next.

  • You deal with the people who do the work
  • No obligation, and no upgrade required before we will help
  • We tell you plainly if something is not worth doing

Send an enquiry

We reply by email. If a server is down, say so in the first line. You can also write to help@scoexpert.com.