Technical article 104996

Installation fails with the error "Exit value 1, Status value 256".

OpenServer 5.0.0

Written · Last revised

Problem

Just after the filesystem has been made, my installation of SCO OpenServer Release 5.0.0 fails with the error:

"Exit value 1, Status value 256".

Cause

There is a fault in the SCO OpenServer Release 5.0.0 kernel that causes the installation kernel to lock onto the wrong partition which results in the "Exit value 1, Status value 256" error.

This may happen if your system has an active DOS or Windows95 partition or no active partition at all.

Solution

This problem has been reported to SCO Engineering.

To work around this problem, try restarting the installation from the beginning. Because the first installation will already have created and activated a Unix partition, the second installation should succeed.

NOTE:     Do not attempt to reactivate the DOS partition as this will recreate
          the failure condition.
If this workaround fails, then the following information may be
of further assistance.  The SCO installation can only succeed
if one of the following conditions holds true:

(1) There is an active Unix partition on the disk (2) There is no active partition on the disk

Sometimes another partition (such as DOS or Windows95) may still be active on your hard disk. If so, you may need to delete existing partition(s), using the fdisk programs for that operating system, in order for the installation to succeed.

NOTE:     You may want to back up your partitions before deleting them as
          fdisk will erase all data in the partition(s).

From the Xinuos technical article database, record 104996. Reproduced with permission. The original is at www.sco.com/ta/104996, which is reachable but blocked from search engines. Xinuos marks this article against a retired product line. That refers to the product’s lifecycle, not to whether the advice still works — plenty of it still applies to running systems.

Next step

Need this fixed rather than explained?

Tell us the release, what the system runs and what it is doing. We will reply by email with what we would do next.

  • You deal with the people who do the work
  • No obligation, and no upgrade required before we will help
  • We tell you plainly if something is not worth doing

Send an enquiry

We reply by email. If a server is down, say so in the first line. You can also write to help@scoexpert.com.