Problem
Installation of SCO OpenServer Release 5.0.0 on an IBM PC
Server 720 may panic with various trap values, but usually
trap 11. This occurs predominately when installing on the
Mylex RAID variety of machine, but it can also occur on the
Adaptec 2940 variety. Cause
The IBM PC Server 720 is a CBUS-II, MCA and PCI architecture. The corollary hardware being used generates spurious interrupts which cause the installation to panic. A system panic will also occur during system running if Support Level Supplement (SLS) OSS411A, the SCO IBM PC Server 720 Installation Supplement, has not been applied using custom.
Solution
During installation, use Support Level Supplement (SLS) OSS411A. This SLS consists of a pre-boot diskette that is also used after installation to custom install the required patch. This disk includes:
1. A new /boot which ensures that spurious interrupts are ignored. This ensures that the installation will not panic.
2. A CDMT custom installable patch which will be installed after the operating system is installed. This ensures that the system does not panic during normal operation.
See the attached SLS OSS411A cover letter for installation instructions.
Dear SCO Customer,The enclosed Support Level Supplement (SLS) OSS411A, the SCO IBM PC Server 720
Installation Supplement, contains a new N0 pre-boot diskette which provides
support for the IBM PC Server 720. It ensures that any spurious interrupts
generated by the hardware are ignored. This enables the system to be
installed and operate correctly.SLS OSS411A applies only to these products:
SCO OpenServer Enterprise System Release 5.0.0 SCO OpenServer Desktop System Release 5.0.0 SCO OpenServer Host System Release 5.0.0
If you have an IBM Server 720 Array model, you also need a VCD (Vendor
Contributed Driver) for the IBM/Mylex DAC960 RAID option from SCO's
Online Support (SOS) system. Check the README file in the VCD Directory
for the latest version and documentation of this driver.NOTE: Earlier versions of SCO Open Server, SCO Open Desktop and SCO UNIX
System V/386 are not supported. This procedure only applies to SCO OpenServer
Release 5.To begin the installation of SCO OpenServer Release 5 using SLS OSS411A:
1. Insert the SLS OSS411A disk.2. Manually reset the system or turn the power on.
3. Wait for the "Boot:" prompt.4. At this point, remove the SLS OSS411A disk and insert the "Boot Disk" from the standard installation set.
For the array model, follow the instructions in Section 1. For the non-array model, follow the instructions in Section 2.
Section 1 - Array model only
============================
For the full procedure, follow the instructions in the letter associated
with the IBM/Mylex DAC960 RAID option. This can be found in the VCD (Vendor
Contributed Driver) section on SCO's Online Support (SOS) system.A brief synopsis follows:a. Type "ahslink". Press <Enter>.b. When prompted to insert the mdac volume, insert the BTLD disk. Press <Enter>.
NOTE: The following messages appear on the screen:
Driver <mdac> apparently should be replaced with the new driver "mdac". Replacing a driver may result in a kernel which does not work.
Please enter 'r' if you wish to try replacement 'a' if you want to use character major 6 [default] which character major number (0-100) to use ('?' to list), or 'q' to quit:
c. Enter "r".d. Continue with the normal installation procedures. When the installation
is complete, you will see the "SAFE to POWER OFF" message.e. Proceed to Section 3.Section 2 - Non-array model only
================================
a. Follow the installation procedures as outlined in the
Release and Installation Notes.b. When the installation is complete, you will see the "SAFE to POWER OFF" message.
c. Proceed to Section 3.Section 3 - Required by array and non-array models
==================================================
a. Insert the SLS OSS411A disk.b. Manually reset the system or turn the power on.
c. Wait for the "Boot:" prompt.d. At this point, leave the SLS OSS411A disk in the floppy disk drive.
e. At the "Boot:" prompt, type:hd(40)unix dump=hd(41) swap=hd(41) root=hd(42)f. After loading text and data, you will see:
Type CONTROL-d to proceed with normal startup,
(or give root password for system maintenance):Enter the root password and press <Enter>.
g. Make sure the SLS OSS411A disk is still in the floppy disk drive.
The patch must now be applied to the IBM PC Server 720. The required
action depends on whether or not the machine will be used as a network
install server. Be aware that loading this patch onto your IBM PC Server
720 will prevent your server from being used as a network install server
for target client machines. Follow the relevant procedure according to
your requirement.1. To allow the patch to be installed from the IBM PC Server 720 over a TCP/IP network, follow the instructions for "LOADING THE PATCH" followed by "APPLYING THE PATCH."
2. To use the patch only on the IBM PC Server 720, follow the instructions for "APPLYING THE PATCH."
If, at a future time, you want to configure the IBM PC Server 720 as a network install server, then you will have to follow the instructions for "LOADING THE PATCH."
INSTALLATION AND REMOVAL INSTRUCTIONSInstalling patches on SCO OpenServer 5.0.0 usually consists of two phases:
"Loading" and "Applying." The instructions that follow enable you to
both install the patch from distribution media or media image, as well
as configure the patch to be installed from a remote SCO OpenServer 5.0.0
system over a TCP/IP network.I. LOADING THE PATCH1. Log in as root.2. Execute the command:# scoadmin software3. Pull down the "Software" menu and select "Patch Management-->Load Patch".
4. You will see the "Begin Load Patch" menu. Be sure the
local machine name is selected and choose "Continue".5. You will see the "Select Media" menu.
As you are loading this supplement from floppy disk
media, select the appropriate floppy disk drive and
choose "Continue". Proceed to step 6.6. You will see the "Load Patch Preference" menu. Choose "Full".7. You will see the "Load Patch Progress" window. If the patch loads
successfully, you will see a "Message" window which states "Load
Patch complete". Choose "OK". You are then returned to the main
Software Manager window.8. To apply the patch now, continue with step 2 under section II,
"Applying the Patch". To exit the Software Manager now, select
"Exit" from the "Host" menu.II. APPLYING THE PATCH1. Log in as root. Execute the command:
# scoadmin software2. Pull down the Software menu and select "Patch Management-->Apply Patch".
3. You will see the "Begin Apply Patch" menu. Be sure that the local
machine name is selected and choose "Continue".4. You will see the "Select Media" menu. The "Hard Disk" menu item
should already be selected. Choose "Continue".5. You will be presented with the "Select a patch product to apply" menu. Highlight the "SCO IBM PC Server 720 Installation Supplement" and choose "Full" to continue.
6. You will see the "Apply Patch Progress" window as the system applies
the patch. If the patch is applied correctly, you will see a NOTE
indicating that:The installation of this patch requires that you recreate your emergency boot floppy. If you have previously created any Network installation client boot floppies these will also have to be recreated.
Press <Enter>. You will again see the "Apply Patch Progress" window, followed by a "Message" window stating "Apply Patch Complete". Choose "OK" and you will be returned to the Software Manager's main menu. Exit the Software Manager by choosing "Exit" from the "Host" menu.
7. When the system has completed "Applying the patch", exit from the "scoadmin software" menu and shut down the system:
# shutdown -g0 -yAfter shutting down and rebooting the machine, application of the patch is complete.
Now install Release Supplement 5.0.0c or 5.0.0d. The installation
procedure is outlined in the Release and Installation Notes.III. NOTES ON NETWORK INSTALLATIONTo install the patch on other SCO OpenServer 5.0.0 machines over the network,
first load the patch, as in section I above, on a designated installation
server. Then create the user "swadmin" on the installation server.When running the Software Manager on the system where the patch will be
installed, you will be prompted for the source location of the patch in
the "Begin Load Patch" window. Be sure to choose "From Another Host"
during this phase. To initiate the installation process you will need to
provide the name of the installation server, as well as the password of
the "swadmin" user on the installation server.NOTE: If SLS OSS411A is loaded onto the IBM PC Server 720, you will be unable
to use this server as a network install server. You will have to install the
target machines by other means and then apply the patch over the network.IV. PATCH REMOVALNOTE: Patches must be rolled back in the reverse order in which they were
installed on a per-component basis. Hence, if the "SCO IBM PC Server 720
Installation Supplement" is not the most recent patch applied to the UNIX
component of the product, you will have to rollback all patches applied
after the "SCO IBM PC Server 720 Installation Supplement" prior to rollback
of the "SCO IBM PC Server 720 Installation Supplement."If you ever want to remove the patch, take these steps:
1. Log in as root.2. Execute the command:# scoadmin softwareor double click on the Software Manager icon in the desktop.
3. Pull down the "Software" menu and select "Patch Management-->Rollback Patch".
4. You will see the "Begin Rollback Patch" menu, and be asked to select patched software to rollback. Select "SCO UNIX System V Operating System" and choose "Continue".
5. You will see the "Patch Selection" window. Make sure that the "SCO IBM PC Server 720 Installation Supplement" is selected, and choose "Continue".
6. You will see the "Confirm Selected Patches" window. Choose "Rollback" to confirm removal of the "SCO IBM PC Server Installation Supplement".
7. You will see the "Rollback Progress" window, as the system
performs the rollback of the patch. If the patch is rolled back
correctly, you will see a NOTE indicating that:The removal of this patch requires that you recreate your emergency boot floppy. If you have previously created any Network installation client boot floppies, these will also have to be recreated to obtain the changes from patch rollback.
Press <Enter>. You will see the "Rollback Progress" window, followed
by a "Message" window stating "Rollback Patch Complete". Choose "OK" and
you will be returned to the Software Manager's main menu. Exit the
Software Manager by choosing "Exit" from the "Host" menu.8. When the system has completed "Rolling back the patch", exit from the "scoadmin software" menu and shut down the system:
# shutdown -g0 -yAfter shutting down and rebooting the machine, rollback of the patch is complete.
9. To also unload the patch, making it no longer available to be applied,
follow the steps in this section. In step 3, choose:"Patch Management-->Unload Patch"instead of:"Patch Management-->Rollback Patch"If you have questions regarding this SLS, or the product on which it is installed, please contact your software supplier.
We appreciate your business.SCO Support Services