Technical article 107622

Intel EtherExpress Pro/100 or Pro/100B NIC isn't working.

OpenServer 5.0.0OpenServer 5.0.6

Written · Last revised

Problem

I've installed the driver, configured the stack, rebuilt the
kernel, and have rebooted the system.  The Pro/100 NIC isn't
working.

Cause

It's possible that the wrong driver is being used, or the driver's speed is set incorrectly.

Solution

Here are some suggestions for debugging the configuration.

There are several things that can prevent either the eeD or eeE
driver from working correctly.  Make sure the correct driver is
installed.  The drivers _cannot_ be interchanged.

The eeD driver supports the EtherExpress Pro/100, PILA8465 or EILA8265.

The eeE driver supports EtherExpress Pro/100B, PILA8465B.

The driver's default speed is usually 100Mbps.  Check that the
configured speed is consistent with the LAN speed.  A driver
configured for 100Mbps operation will not operate correctly on
a 10Mbps LAN.  Use netconfig(ADM) to examine and configure the
driver.  Select the "Advanced Option" button and select either
"Auto" or "10Mbps" for a 10Mbps LAN.
Examine the LEDs on the NIC endplate.  Is the bottom LED, marked
"100", glowing?  Is the top LED, marked "Link", dark?  This
combination indicates that the card is configured for 100Mbps
operation and has not been able to establish link at that speed.
Alternatively, in the /etc/conf/pack.d/<driver> directory, modify
the space.c file.  The directory name will be either "eeD" or
"eeE".  In the space.c file there is a variable of the form
EEE_0_MSPEED (for the eeE driver), or EED_0_MSPEED (for the eeD
driver).  The variable's value can be set to "0" for "Auto", "10"
for 10 Mbps, or "100" for 100Mbps.

Modifying the driver either by using netconfig(ADM) or by editing the space.c file, will require that the kernel be relinked. Relink the kernel and reboot the machine.

See also

TA101579, "Which Intel networking products are supported in the SCO environment?"

From the Xinuos technical article database, record 107622. Reproduced with permission. The original is at www.sco.com/ta/107622, which is reachable but blocked from search engines. Xinuos marks this article against a retired product line. That refers to the product’s lifecycle, not to whether the advice still works — plenty of it still applies to running systems.

Next step

Need this fixed rather than explained?

Tell us the release, what the system runs and what it is doing. We will reply by email with what we would do next.

  • You deal with the people who do the work
  • No obligation, and no upgrade required before we will help
  • We tell you plainly if something is not worth doing

Send an enquiry

We reply by email. If a server is down, say so in the first line. You can also write to help@scoexpert.com.