Technical article 105862

Message Timeout Error M=3D T=3 on OpenServer 5.0.2.

OpenServer 5.0.2

Written · Last revised

Problem

The following message appears on the system console on bootup:

Message Timeout Error: M=3D T=3 Error : Error Returned From Engine, Program Terminated!!

Where is this coming from and what does it mean?

Cause

This message is coming from a DPT RAID controller logger program that is running on the system. The logger appears to be timing out.

Solution

The logger timeout value can be increased from its current value by editing the CMDTIME parameter setting within the "/usr/dpt/dptelog.def" file.

For further information and support on DPT issues, contact Data Processing Technologies Customer Support or your hardware supplier.

See also

http://www.dpt.com

From the Xinuos technical article database, record 105862. Reproduced with permission. The original is at www.sco.com/ta/105862, which is reachable but blocked from search engines. Xinuos marks this article against a retired product line. That refers to the product’s lifecycle, not to whether the advice still works — plenty of it still applies to running systems.