Technical article 105801

My Liant RM/COBOL application keeps running after I log out of my 5.0.x system.

OpenServer 5.0.0OpenServer 5.0.2OpenServer 5.0.4

Written · Last revised

Problem

After I log out, or improperly exit, my COBOL application is still running. I'm using Liant RM/COBOL version 5.36. This version of COBOL worked fine on SCO UNIX System V/386 Release 3.2 Operating System Version 4.2.

Cause

Liant RM/COBOL version 5.36 does not respond to the HUP signal, which is the method of stopping child processes upon logout.

Solution

Upgrade to Liant RM/COBOL version 6.09.04, which is compatible with SCO OpenServer Release 5.0.0, 5.0.2 and 5.0.4.

See also

kill(C), signal(S)

From the Xinuos technical article database, record 105801. Reproduced with permission. The original is at www.sco.com/ta/105801, which is reachable but blocked from search engines. Xinuos marks this article against a retired product line. That refers to the product’s lifecycle, not to whether the advice still works — plenty of it still applies to running systems.

Next step

Need this fixed rather than explained?

Tell us the release, what the system runs and what it is doing. We will reply by email with what we would do next.

  • You deal with the people who do the work
  • No obligation, and no upgrade required before we will help
  • We tell you plainly if something is not worth doing

Send an enquiry

We reply by email. If a server is down, say so in the first line. You can also write to help@scoexpert.com.