Technical article 101282

NetWare Gateway gives the error "You cannot connect to server <Server>" or "nwlogin not available"

OpenServer 5.0.0

Written · Last revised

Problem

When the eighth SCO Gateway for NetWare user attempts to log in to the NetWare server, this error message is displayed:

You cannot connect to server <NetWare-Server>

The NetWare license supports more than eight users.

Solution

By default, SCO Gateway for NetWare is configured to allow
eight users to log in to the NetWare server.  This limit is
configured using the kernel tuneable parameter NUCUSERS,
NUCLOGINS, and NUCNWMPOPENS. The value of all of these must be
greater than the maximum number of users who will concurrently
require access to NetWare resources.
Tuneable parameters which are changed from the default are
defined in the file:
/etc/conf/cf.d/stune
If a parameter is not defined in this file,  the default
value defined in /etc/conf/cf.d/mtune is used.

In order to increase the value of NUCUSERS from 8 to 32, you will need to be logged into your system as root and execute these commands:

# cd /etc/conf/bin
# ./idtune NUCUSERS 32
The system will respond with:

Tuneable Parameter "NUCUSERS" is currently set to 8. Is it OK to change it to 32 ? (y/n)

Similar idtune commands should be issued for the NUCNWMPOPENS and
NUCLOGINS parameters. In addition, if these parameters are being
set to values greater than 23, the number of ipx sockets configured
must also be increased. Do this by editing
/etc/conf/pack.d/ipx/ipx_tune.h
find the line
#define IPX_MAX_SOCKETS 100

Change this to a value of 4*(NUCLOGINS+2), i.e. 136 for the example of 32 NUCLOGINS. The kernel must be rebuilt, and the system rebooted for these changes to take effect:

# cd /etc/conf/cf.d
# ./link_unix -y
# shutdown -y -g0

See also

See the stune(F),  mtune(F) and idtune(ADM) manual
pages for further details.

From the Xinuos technical article database, record 101282. Reproduced with permission. The original is at www.sco.com/ta/101282, which is reachable but blocked from search engines. Xinuos marks this article against a retired product line. That refers to the product’s lifecycle, not to whether the advice still works — plenty of it still applies to running systems.

Next step

Need this fixed rather than explained?

Tell us the release, what the system runs and what it is doing. We will reply by email with what we would do next.

  • You deal with the people who do the work
  • No obligation, and no upgrade required before we will help
  • We tell you plainly if something is not worth doing

Send an enquiry

We reply by email. If a server is down, say so in the first line. You can also write to help@scoexpert.com.