Technical article 105853

No login prompts appear on multiscreens after installing Release Supplement 504C.

OpenServer 5.0.4OpenServer 5.0.5

Written · Last revised

Problem

After installing Release Supplement 504C on SCO OpenServer 5.0.4 there are no login prompts (getty processes) displayed on the multiscreens. The graphical login screen is working as normal.

This problem has been seen when the Release Supplement 504C is installed on a system which also has the AMI MegaRAID AMIRD third party driver package installed. See below for details of other RAID controllers which may also result in this problem.

Cause

The way in which the system logs information when booting to
multiuser mode has been modified slightly with the Release
Supplement 504C. The AMIRD driver package installs a startup
script in /etc/idrc.d which is run by the /etc/rc2 shell script
when booting to multiuser mode. This script then executes the
/etc/amirdmon binary.  The AMIRD program together with the new
logging method results in the above problem.

Solution

This problem is resolved in Support Level Supplement (SLS) OSS497 and Release Supplment 505A (rs505a) for SCO OpenServer Release 5.0.5. For OpenServer 5.0.4 systems, the procedure below should work around the problem.

Edit the /etc/rc2 script and modify the following line so the "$LOGCMD" string is commented out with a hash character (#) as shown:

if [ -d /etc/idrc.d ]
then
        for f in /etc/idrc.d/*
        {
                if [ -s ${f} ]
                then
                        /bin/sh ${f}
                fi
        } 2>&1 | $LOGCMD
To:
if [ -d /etc/idrc.d ]
then
        for f in /etc/idrc.d/*
        {
                if [ -s ${f} ]
                then
                        /bin/sh ${f}
                fi
        } 2>&1 # | $LOGCMD

Save the file and reboot the system. The login prompts should now appear as normal.

NOTE:     Currently, this problem has been seen with the AMI MegaRAID Ultra
          PCI AMIRD driver package Release 1.42, the HP NetRAID, and the
          Mylex RAID controllers, when used with the Release Supplement
          504C.

See also

Manual page: rc2(ADM)

From the Xinuos technical article database, record 105853. Reproduced with permission. The original is at www.sco.com/ta/105853, which is reachable but blocked from search engines.

Next step

Need this fixed rather than explained?

Tell us the release, what the system runs and what it is doing. We will reply by email with what we would do next.

  • You deal with the people who do the work
  • No obligation, and no upgrade required before we will help
  • We tell you plainly if something is not worth doing

Send an enquiry

We reply by email. If a server is down, say so in the first line. You can also write to help@scoexpert.com.