Problem

After upgrading to SCO OpenServer 5, telnet and X Windows sessions from systems other than those on the local network have started to hang when large amounts of data are sent, such as a login banner.

Cause

SCO TCP/IP now implements Path MTU Discovery by default as specified
by the RFC 1191. This results in the 'Don't Fragment' bit being set
in the IP header. If the minimum MTU size supported for a particular
route is too small for the packet to be delivered, an ICMP error
packet will be returned. SCO TCP/IP does not always react to the
ICMP error and retransmits the packet unchanged.

Solution

This problem has been reported to SCO Engineering.

The TCP/IP Path MTU Discovery can be disabled by altering the value of the 'ip_perform_pmtu' parameter contained in the file "/etc/default/inet". The default setting is 1 - enabled. Use the inconfig(ADMN) command to modify the file.

The current setting for the 'ip_perform_pmtu' parameter can be found using:

# inconfig ip_perform_pmtu
inconfig: symbol ip_perform_pmtu has current value 1, minimum 0,
maximum 1

Modify the setting in order to disable Path MTU Discovery:

# inconfig ip_perform_pmtu 0
Check the setting:
# inconfig ip_perform_pmtu
inconfig: symbol ip_perform_pmtu has current value 0, minimum 0,
maximum 1

Restart your system. The '/etc/inconfig' utility is invoked by the "/etc/rc2.d/S85tcp" startup file when the system enters multiuser mode.

See also

RFC 1191 J. Mogul, S. Deering, "Path MTU Discovery", 11/16/1990 for a concise description of the mechanism used to implement this enhancement.

From the Xinuos technical article database, record 107615. Reproduced with permission. The original is at www.sco.com/ta/107615, which is reachable but blocked from search engines. Xinuos marks this article against a retired product line. That refers to the product’s lifecycle, not to whether the advice still works — plenty of it still applies to running systems.

Next step

Need this fixed rather than explained?

Tell us the release, what the system runs and what it is doing. We will reply by email with what we would do next.

  • You deal with the people who do the work
  • No obligation, and no upgrade required before we will help
  • We tell you plainly if something is not worth doing

Send an enquiry

We reply by email. If a server is down, say so in the first line. You can also write to help@scoexpert.com.