Technical article 110211

SCO OpenServer fails to recognize the CD-ROM during installation on a ProLiant 5500.

OpenServer 5.0.5

Written · Last revised

Problem

SCO OpenServer Host and SCO OpenServer Enterprise System Release 5.0.5 fails to recognize any combination of EIDE CD-ROM settings (primary/secondary controller, master/slave device) when specifying the media device during installation.

Cause

The jumper at the back of the CD-ROM unit in this machine is set at the CS position by default, which prevents OpenServer from detecting it.

Solution

Change the CD-ROM jumper to the MA (Master) position before beginning the installation, then specify that the EIDE CD-ROM is the Master device on the Primary controller when configuring the media device.

Note that access to the CD-ROM jumper will require a partial disassembly of the server, and should therefore only be carried out by a Compaq-authorized engineer.