Problem
Setting the kernel parameter "STRMSGSZ" to a value of 65536 causes scologin to hang.
Solution
This issue is fixed in SCO OpenServer Release 5.0.6.
For earlier releases, if you set STRMSGSZ back to its original value of 16348, your graphical login will return the next time you relink the kernel and reboot the system.
According to the SCO OpenServer 5 Performance Guide, STRMSGSZ is
the maximum allowable size of the data portion of any STREAMS
message. This should usually be set so that it is just large
enough to accommodate the maximum packet size restrictions of
the configured STREAMS modules. The default value of 16384 is
sufficient for most applications.