Technical article 105054

syslog receives "telnetd: [pid] can't find utmp entry for ptty" errors.

OpenServer 5.0.0

Written · Last revised

Problem

Every 10-15 seconds, my /usr/adm/syslog file is updated with the error:

telnetd: [pid] can't find utmp entry for ptty [xxx]

where [pid] and tty number [xxx] will vary.

Cause

There is a known conflict with OpenServer Release 5's telnetd and some of the earlier versions of the Compaq Insight Manager agents.

Solution

Compaq is aware of this problem and has a fix available on either
ftp.compaq.com or www.compaq.com, or from Compaq Technical Support.
The fix is called "SP1622.EXE".

If you are not using a SNMP-based management environment, you can disable monitoring tools provided with Compaq Insight Manager with the command:

cpqsmux stop
Alternatively, you can change the file /etc/rc2.d/S98cpqsmux to
 /etc/rc2.d/s98cpqsmux (change the "S" to "s") so that the script
 is not run while going into multiuser mode.  This will permanently
 prevent the Insight Manager agents from starting up.

If, however, you need the tools to monitor the fault and performance of key server subsystems in your SNMP environment, you should contact Compaq Technical Support and request the updated Insight Manager mentioned above.

From the Xinuos technical article database, record 105054. Reproduced with permission. The original is at www.sco.com/ta/105054, which is reachable but blocked from search engines. Xinuos marks this article against a retired product line. That refers to the product’s lifecycle, not to whether the advice still works — plenty of it still applies to running systems.

Next step

Need this fixed rather than explained?

Tell us the release, what the system runs and what it is doing. We will reply by email with what we would do next.

  • You deal with the people who do the work
  • No obligation, and no upgrade required before we will help
  • We tell you plainly if something is not worth doing

Send an enquiry

We reply by email. If a server is down, say so in the first line. You can also write to help@scoexpert.com.