Problem

The correct License Number, Code, and Data, is entered, but is not accepted.

Cause

There is a confusing window in the Software Manager which allows a user to install the Development System incorrectly. The 'Select Product to Install' window (from Software Manager -> Software -> Install New) lists 3 options for install: SCO OpenServer Software, SCO Merge, SCO Symmetrical Multiprocessing followed by a blank line which leads the user to think there are no more options.

Clicking on 'OpenServer Software' displays a second window with the Development System listed as part of the OpenServer product. Highlighting 'Development System' here and clicking on 'Install' does the initial load of the Development System then asks for the license.

Entering the Development System license information will not work and a window displays with the statement:

The license information you entered is not for SCO OpenServer Software, which you are currently licensing. Please check that you are using the correct Certificate of License and Authenticity for SCO OpenServer Software.

If licensing is deferred, the Development System software will load successfully, but attempting to license through the License Manager later will also fail.

Solution

On the 'Select Product To Install' window move the scroll bar down to see more options which should include SCO Development System (ver 5.0.0b). Highlight this option and click on Full to install the entire Development System product.

The License Number, Code, and Data should now be accepted when entered either during installation or later through the License Manager.

This has been reported to SCO Engineering.

From the Xinuos technical article database, record 100763. Reproduced with permission. The original is at www.sco.com/ta/100763, which is reachable but blocked from search engines. Xinuos marks this article against a retired product line. That refers to the product’s lifecycle, not to whether the advice still works — plenty of it still applies to running systems.

Next step

Need this fixed rather than explained?

Tell us the release, what the system runs and what it is doing. We will reply by email with what we would do next.

  • You deal with the people who do the work
  • No obligation, and no upgrade required before we will help
  • We tell you plainly if something is not worth doing

Send an enquiry

We reply by email. If a server is down, say so in the first line. You can also write to help@scoexpert.com.