Technical article 105361

WARNING: mdac IOCTL called with: dev=0x00001300 cmd=1145110275 arg=0x0804B7D4 mode=1.

OpenServer 5.0.0OpenServer 5.0.2

Written · Last revised

Problem

I am getting the following warning messages appearing on my console:

WARNING: mdac IOCTL called with: dev=0x00001300 cmd=1145110275 arg=0x0804B7D4 mo de=1

Cause

This error message indicates that the Mylex DAC960 Driver has received an unknown ioctl(S) command.

The dac960mon(ADM) utility provided with SCO OpenServer Release 5 systems should only be used in conjunction with the SCO supplied mdac driver. If your system is running with a Mylex DAC960 PCI card and Mylex BTLD and the SCO version of dac960mon(ADM) is running, your system console will display the warning message shown above.

Some releases of the Mylex DAC960 PCI BTLD do not replace the dac960mon(ADM) utility, thus causing this problem.

Solution

Get the latest Mylex DAC960 PCI BTLD from the following Web site:

http://www.mylex.com/support/index.html

To temporarily disable the messages, take the system into single-user (maintenance) mode and move the file /etc/rc2.d/S00MDAC as follows:

mv /etc/rc2.d/S00MDAC /etc/rc2.d/s00MDAC

This will ensure that the dac960mon(ADM) utility is not started next time the system is taken into multiuser mode.

From the Xinuos technical article database, record 105361. Reproduced with permission. The original is at www.sco.com/ta/105361, which is reachable but blocked from search engines. Xinuos marks this article against a retired product line. That refers to the product’s lifecycle, not to whether the advice still works — plenty of it still applies to running systems.

Next step

Need this fixed rather than explained?

Tell us the release, what the system runs and what it is doing. We will reply by email with what we would do next.

  • You deal with the people who do the work
  • No obligation, and no upgrade required before we will help
  • We tell you plainly if something is not worth doing

Send an enquiry