Technical article 105794

WARNING or NOTICE messages from ida0 after installing Compaq EFS 5.15.

OpenServer 5.0.4

Written · Last revised

Problem

After installing SCO OpenServer Release 5.0.4 and the Compaq Extended Feature Supplement (EFS) 5.15, I notice a large number of disk errors such as:

WARNING: ida-266225236: Polling for alarms command failed.

Or:

NOTICE: ida0: slot 1: invalid request on dev 255/255 blk 0 logical unit=0, block=0, size=1, cmd=0x65, status=0x10

Cause

SCO OpenServer Enterprise 5.0.4 requires Compaq EFS 5.15 or later. This EFS replaces the stock IDA drivers with newer versions designed to work with updated IDA controllers currently being shipped by Compaq.

If you have a SMART-2, or later, controller you may want to use the enhanced drivers found in EFS 5.15 with OpenServer 5.0.4. However, if you have an older IDA controller, you may have better results with the existing IDA.

Solution

Run the command "/usr/lib/custom/save/cpqefs/ida.restore" to
replace the new IDA drivers with the original OpenServer Release
5.0.4 version.  The original OpenServer 5.0.4 IDA drivers are
stored in the /usr/lib/custom/save/cpqefs directory in case they
are needed for older IDA hardware.

Be sure to read the warning message and double-check your hardware before changing drivers.

You will need to relink your kernel and reboot before the original IDA drivers will be used.

NOTE:     Use /usr/bin/compaq/diags/ida/ida_menu to check the performance of the
          IDA controller which is provided by the Compaq EFS.

See also

ida(HW) man page

From the Xinuos technical article database, record 105794. Reproduced with permission. The original is at www.sco.com/ta/105794, which is reachable but blocked from search engines. Xinuos marks this article against a retired product line. That refers to the product’s lifecycle, not to whether the advice still works — plenty of it still applies to running systems.

Next step

Need this fixed rather than explained?

Tell us the release, what the system runs and what it is doing. We will reply by email with what we would do next.

  • You deal with the people who do the work
  • No obligation, and no upgrade required before we will help
  • We tell you plainly if something is not worth doing

Send an enquiry

We reply by email. If a server is down, say so in the first line. You can also write to help@scoexpert.com.