Technical article 110050

What Date and Time processing fixes are included in SLS OSS600A?

OpenServer 5.0.5

Written · Last revised

Problem

What date and time processing problems are fixed in Support Level Supplement (SLS) OSS600A?

Solution

SLS OSS600A addresses a number of date and time processing issues on SCO OpenServer Release 5.0.5-based systems that have Release Supplement 505A applied.

The issues addressed by SLS OSS600A are:

The convertclock(VTCL) function in /bin/vtcl fails with the error
"Fatal error: Unable to convert date-time string "00:00"" in the
year 2000.  Associated SCO tracking number: SCO-247-141

getdate(S) can generate unreliable results if "%y" is used in the DATEMSK for the API and the year is 2000. Associated SCO tracking number: RUS-1-39

lastlogin(ADM) does not treat 2-digit year values correctly beyond 1999. Associated SCO tracking number: RUS-1-22

mcart(C), the Irwin tape drive control utility, displays the year 20YY as 1YY. Associated SCO tracking number: SCO-247-146

scosh(C) email summary window displays the year as "-9" for a
message with a year of 101 (2001 with the mail(C) bug).  Associated
SCO tracking number: SCO-59-9801

Commands and utilities display time and date in English regardless of locale. Associated SCO tracking number: SCO-59-9814

See also

ta110051, "What Date and Time processing fixes are included in SLS OSS601A?"

From the Xinuos technical article database, record 110050. Reproduced with permission. The original is at www.sco.com/ta/110050, which is reachable but blocked from search engines.

Next step

Need this fixed rather than explained?

Tell us the release, what the system runs and what it is doing. We will reply by email with what we would do next.

  • You deal with the people who do the work
  • No obligation, and no upgrade required before we will help
  • We tell you plainly if something is not worth doing

Send an enquiry

We reply by email. If a server is down, say so in the first line. You can also write to help@scoexpert.com.