Problem
What date and time processing problems are fixed in Support Level Supplement (SLS) OSS600A?
Solution
SLS OSS600A addresses a number of date and time processing issues on SCO OpenServer Release 5.0.5-based systems that have Release Supplement 505A applied.
The issues addressed by SLS OSS600A are:
The convertclock(VTCL) function in /bin/vtcl fails with the error
"Fatal error: Unable to convert date-time string "00:00"" in the
year 2000. Associated SCO tracking number: SCO-247-141getdate(S) can generate unreliable results if "%y" is used in the DATEMSK for the API and the year is 2000. Associated SCO tracking number: RUS-1-39
lastlogin(ADM) does not treat 2-digit year values correctly beyond 1999. Associated SCO tracking number: RUS-1-22
mcart(C), the Irwin tape drive control utility, displays the year 20YY as 1YY. Associated SCO tracking number: SCO-247-146
scosh(C) email summary window displays the year as "-9" for a
message with a year of 101 (2001 with the mail(C) bug). Associated
SCO tracking number: SCO-59-9801Commands and utilities display time and date in English regardless of locale. Associated SCO tracking number: SCO-59-9814
See also
ta110051, "What Date and Time processing fixes are included in SLS OSS601A?"