Technical article 109660

What is (SLS) APP479A, the Merge 4 EXPIRED_LICENSE patch?

OpenServer 5.0.4

Written · Last revised

Problem

When invoking an SCO Merge, DOS or Windows session using an SCO Merge Desktop 2-user or Non-commercial Merge license, Merge incorrectly returns the error:

EXPIRED_LICENSE:dos: The license to use Merge has expired. To use Merge you must remove the current license and install a new one.

This can occur even when the license is still valid and the user-limit has not been exceeded. Persistent attempts usually result in a successful startup of a DOS or Windows session. Rebooting the system will also temporarily resolve this problem.

Cause

This problem is caused by a bug in the Merge policy code in the Policy Manager Daemon (ifor_pmd).

Solution

Support Level Supplement (SLS) APP479A, the Merge 4 EXPIRED_LICENSE Patch, corrects this spurious Merge "EXPIRED_LICENSE" error by addressing a problem in the Policy Manager Daemon.

See the attached cover letter that accompanies this SLS for more information, including installation instructions.

NOTES:    SLS APP479A is only intended for SCO OpenServer Release 5.0.4 or
          SCO OpenServer 5.0.4 with Release Supplement rs504c installed.

This issue is resolved in SCO OpenServer Release 5.0.5.

Dear SCO Customer,

Support Level Supplement (SLS) APP479A, the Merge 4 EXPIRED_LICENSE patch, corrects a problem in the Policy Manager Daemon (ifor_pmd) that causes Merge to output an incorrect "EXPIRED_LICENSE" error.

Software Notes and Recommendations
----------------------------------

SLS APP479A is intended for use on all versions of SCO OpenServer Release 5.0.4 (including those that have had Release Supplement rs504c installed) where a Merge Desktop or Free Merge license is installed.

The problem is resolved in SCO OpenServer Release 5.0.5.

I. INSTALLING SLS APP479A
1. Prepare the media for installation.

Download the APP479A media image file (app479a file), place the file in the /tmp directory, and rename the file by typing the following commands:

mv /tmp/app479a /tmp/VOL.000.000

2. Run the Software Manager with the command:

# scoadmin software

or double-click on the Software Manager icon in the desktop.

3. Pull down the "Software" menu and select "Install New".

4. When prompted for the host from which to install, choose the local machine and then "Continue".

5. When prompted to select the media device:

If you are installing this SLS from diskette media, select the appropriate floppy disk drive and then "Continue". Proceed to step 6.

If you are installing this SLS from media images per step 1, select
"Media Images", then "Continue".  When prompted for the "Image
Directory", enter "/tmp" (or the directory where you placed the VOL
file in step 1) and then select "OK".

6. When prompted to select software to install, ensure that the "APP479A" entry is highlighted. Choose "Install".

7. Once the installation finishes, quit the Software Manager.

8. Reboot the system to use the new kernel. Installation of SLS APP479A is now complete.

II. REMOVING SLS APP479A
Note: Patches must be rolled back in the reverse order in which they
were installed on a per-component basis.  Hence, if the Merge 4
EXPIRED_LICENSE  patch is not the most recent patch applied to the
UNIX component of the product, you will have to roll back all patches
applied after the Merge 4 EXPIRED_LICENSE patch prior to rollback of
the Merge 4 EXPIRED_LICENSE patch.
1. Log in as root.
2. Execute the command:
# scoadmin software

or double-click on the Software Manager icon in the desktop.

3. Highlight "APP479A: Merge 4 EXPIRED_LICENSE patch".

4. Pull down the "Software" menu and select "Remove Software".

5. Once the removal finishes, quit the Software Manager.

6. Reboot the system to use the rebuilt kernel. Removal of SLS APP479A is now complete.

If you have questions regarding this SLS, or the product on which it is installed, please contact your software supplier.

We appreciate your business.

From the Xinuos technical article database, record 109660. Reproduced with permission. The original is at www.sco.com/ta/109660, which is reachable but blocked from search engines. Xinuos marks this article against a retired product line. That refers to the product’s lifecycle, not to whether the advice still works — plenty of it still applies to running systems.

Next step

Need this fixed rather than explained?

Tell us the release, what the system runs and what it is doing. We will reply by email with what we would do next.

  • You deal with the people who do the work
  • No obligation, and no upgrade required before we will help
  • We tell you plainly if something is not worth doing

Send an enquiry

We reply by email. If a server is down, say so in the first line. You can also write to help@scoexpert.com.