Problem
I have learned that errata have been identified for the Pentium
Pro and the Pentium II CPUs. Are patches available from SCO to
work around these errata? Solution
Intel has identified errata with the Pentium Pro processor and
the Pentium II processor which could affect software running on
SCO operating systems. This is known as the "call gates" errata.
Another cpu-related issue involves the SIGSEGV issue. Support
Level Supplement (SLS) OSS458A addresses these areas.These errata are only relevant to a multiprocessor system. SLS OSS458A can only be installed on systems on which SCO SMP is installed.
NOTE: SLS OSS458A is not needed for (nor is it installable on)
SCO OpenServer 5.0.4. The patch included for SLS OSS458A is
included in the SCO OpenServer 5.0.4 Release Supplement, rs504c.See the attached cover letter that accompanies SLS OSS458A for further information, including installation instructions.
Dear SCO Customer,The enclosed Support Level Supplement, (SLS) OSS458A, corrects problems with the Intel Pentium Pro and Pentium II CPUs, known as "call gates", as well a SIGSEGV issue.
RELEASE INFORMATIONSLS OSS458A is intended for use on these products:
SCO OpenServer Host System Release 5.0.2 SCO OpenServer Desktop System Release 5.0.2 SCO OpenServer Enterprise System Release 5.0.2
INSTALLATION AND REMOVAL INSTRUCTIONSInstalling patches on SCO OpenServer Release 5 usually consists of
two phases: "Loading" and "Applying". The instructions that follow
enable you to both install the patch from distribution media or media
image, as well as configure the patch to be installed from a remote
SCO OpenServer Release 5 system over a TCP/IP network.I. LOADING THE PATCH1. Log in as root.2. If you are installing this SLS from floppy disk media, skip
this step and proceed to step 3.If you are installing this SLS from a media image, there is a
file called oss458a.Z. Uncompress this file with this command:# uncompress oss458a.ZCopy the file to the /tmp directory and name it VOL.000.000:
# cp oss458a /tmp/VOL.000.0003. Execute the command:# scoadmin softwareor double click on the Software Manager icon on the desktop.
4. Pull down the "Software" menu and select "Patch Management-->Load Patch".5. You will see the "Begin Load Patch" menu. Be sure the local machine
name is selected and choose "Continue".6. You will see the "Select Media" menu.a. If you are loading this SLS from floppy disk media,
select the appropriate floppy disk drive and choose
"Continue". Proceed to step 7.b. If you are loading this SLS from a media image per step 2,
pull down the "Media Device" menu and select "Media Images",
then choose "Continue". You will then see the "Enter Image
Directory" menu. Enter /tmp and choose "OK".7. You will see the "Load Patch Preference" menu. Choose "Full".8. You will see the "Load Patch Progress" window. If the patch loads
successfully, you will see a "Message" window which states "Load
Patch complete". Choose "OK". You are then returned to the main
Software Manager window.9. To apply the patch now, continue with step 2 under section II,
"Applying the Patch". To exit the Software Manager now, select
"Exit" from the "Host" menu.II. APPLYING THE PATCH1. Log in as root. Execute the command:# scoadmin softwareor double click on the Software Manager icon on the desktop.
2. Pull down the Software menu and select "Patch Management-->Apply Patch".3. You will see the "Begin Apply Patch" menu. Be sure that the local
machine name is selected and choose "Continue".4. You will see the "Select Media" menu. The "Hard Disk" menu item should
already be selected. Choose "Continue".5. You will be presented with the "Select Patch-product to Apply" menu.
Highlight the "Intel Processor Supplement" patch and then choose
"Full" to continue.6. You will see the "Apply Patch Progress" window as the system applies
the patch.7. You will see this message:NOTE: Application or rollback of this patch requires a kernel
relink. If you are applying or rolling back several
patches at this time, you may choose to defer the
relink until the last patch application or rollback.
Do you want to relink the kernel now? (y/n)Enter "y" or "n" based on this message. Note that you will not be able to make use of the patch until you relink the kernel. Therefore, it is suggested that you answer "y" to this question.
8. If you chose "y", the kernel will be relinked. In either case, you
will then see:Press <Enter> to continueAfter pressing <Enter>, you will see the "Apply Patch Progress" window,
after which you will see a "Message" window stating "Apply Patch
Complete". Choose "OK" and you will be returned to the Software
Manager's main menu. Exit the Software Manager by choosing "Exit" from
the "Host" menu.9. Log in as root on tty01, and shut down the system:# shutdown -g0 -yAfter shutting down and rebooting the machine, application of the patch is complete.
III. NOTES ON NETWORK INSTALLATIONTo install the patch on other SCO OpenServer 5.0.0 machines over the network, first load the patch as in section I above on a designated installation server. Then create the user "swadmin" on the installation server.
When running the Software Manager on the system where the patch will be
installed, you will be prompted for the source location of the patch in the
"Begin Load Patch" window. Be sure to choose "From Another Host" during this
phase. You will need to provide the name of the installation server, as well
as the password of the "swadmin" user on the installation server, to initiate
the installation process.IV. PATCH REMOVALNOTE: Patches must be rolled back in the reverse order in which they were
installed on a per-component basis. Hence, if the OSS458A patch is not the
most recent patch applied to the UNIX component of the product, you will have
to roll back all patches applied after the OSS458A patch prior to rollback of
the OSS458A patch.1. Log in as root.2. Execute the command:# scoadmin softwareor double click on the Software Manager icon in the desktop.
3. Pull down the "Software" menu and select "Patch Management-->
Rollback Patch".4. You will see the "Begin Rollback Patch" menu, and be asked to select
patched software to roll back. Select "SCO UNIX System V Operating System"
and choose "Continue".5. You will see the "Patch Selection" window. Make sure that the Intel
Processor patch is selected, and choose "Continue".6. You will see the "Confirm Selected Patches" window. Choose "Rollback"
to confirm removal of the OSS458A patch.7. You will see the "Rollback Progress" window, as the system performs
the rollback of the patch.8. You will see this message:NOTE: Application or rollback of this patch requires a kernel
relink. If you are applying or rolling back several
patches at this time, you may choose to defer the
relink until the last patch application or rollback.
Do you want to relink the kernel now? (y/n)Enter "y" or "n" based on this message. Note that complete rollback of this patch requires a relink of the kernel to be complete. Therefore, it is suggested that you answer "y" to this question, unless you are installing or removing other patches.
9. If you chose "y", the kernel will be relinked. In either case, you will
then see:Press <Enter> to continueAfter pressing the <Enter> key, you will see the "Rollback Progress" window, after which a "Message" window stating "Rollback Patch Complete". Choose "OK" and you will be returned to the Software Manager's main menu. Exit the Software Manager by choosing "Exit" from the "Host" menu.
10. Log in as root on tty01, and shut down the system:
# shutdown -g0 -yAfter shutting down and rebooting the machine, rollback of the patch is complete.
11. To also unload the patch, making it no longer available to be applied,
follow steps 1 through 10 in this section. However, in step 3, choose:"Patch Management-->Unload Patch"instead of:"Patch Management-->Rollback Patch"If you have questions regarding this SLS, or the product on which it is installed, please contact your software supplier.
We appreciate your business.SCO Support Services