Technical article 115162

What is SLS OSS642A, the Cron supplement?

OpenServer 5.0.4OpenServer 5.0.5OpenServer 5.0.6

Written · Last revised

Problem

Support Level Supplement (SLS) OSS642A, the Cron Supplement, addresses various problems in the cron daemon, including these:

- Cron jobs can sometimes be run twice (jobs are duplicated) - Cron jobs can be started too early - Memory leaks occur in cron

Solution

OSS642A provides a new /etc/cron daemon, as well as updated versions of the /usr/bin/at and /usr/bin/crontab utilities.

See the attached cover letter that accompanies this SLS for more information, including installation instructions.

NOTE:     This paragraph only applies if the system is operating in "High"
          security mode. Before installation, or removal, of OSS642A per
          instructions below, it is strongly recommended that the system be
          brought down to single-user mode.  OSS642A restarts cron after both
          installation and removal of the new cron daemon, but it fails
          to do so properly, and as a result, crontab and at jobs may
          subsequently fail to run.  This problem can be worked around
          by simply performing installation or removal from single-user
          mode.  This problem will be resolved in a future revision of
          OSS642A.
Dear SCO Customer,

Support Level Supplement (SLS) OSS642A, the Cron Supplement, addresses various problems in the cron daemon, including the "job sometimes runs twice" problem.

Software Notes and Recommendations
----------------------------------

SLS OSS642A is intended for use on these products:

SCO OpenServer Release 5.0.4 SCO OpenServer Release 5.0.5 SCO OpenServer Release 5.0.6 SCO OpenServer Release 5.0.6A

OSS642A will be included in all OpenServer releases AFTER release 5.0.6A, and should, therefore, not be installed on such systems.

Installation Instructions
-------------------------

1. Download the OSS642A media image file (oss642a file), place the file in the /tmp directory, then rename the file by typing the following:

cd /tmp
mv oss642a VOL.000.000

2. Run the Software Manager with the command:

# scoadmin software

or double-click on the Software Manager icon in the desktop.

3. Pull down the "Software" menu and select "Install New".

4. When prompted for the host from which to install, choose the local machine and then "Continue".

5. In the "Select Media" menu, pull down the "Media Device" menu.  Select
   "Media Images", then choose "Continue".

6. When prompted for the "Image Directory", enter "/tmp" (or the directory where you placed the VOL file in step 1 and choose "OK".

7. When prompted to select software to install, make sure that the
   "OSS642a - Cron supplement" entry is highlighted.  Choose "Install".
8. Installation of SLS OSS642A is now complete.  To exit the Software Manager,
   select "Exit" from the "Host" menu.
Removal Instructions
--------------------
Note: Patches must be rolled back in the reverse order in which they were
      installed on a per component basis.  That is, if OSS642A (the Cron
      Supplement) is not the most recent patch applied to the UNIX component
      of the product, you will have to roll back all patches applied after
      OSS642A prior to rollback of OSS642A.

To remove SLS OSS642A, take these steps:

1. Log in as root.
2. Execute the command:
# scoadmin software

or double-click on the Software Manager icon in the desktop.

3. Highlight "OSS642a - Cron supplement".

4. Pull down the "Software" menu and select "Remove Software".

5. Once the removal finishes, quit the Software Manager.  Removal of
   SLS OSS642A is now complete.

If you have questions regarding this SLS, or the product on which it is installed, please contact your software supplier.

From the Xinuos technical article database, record 115162. Reproduced with permission. The original is at www.sco.com/ta/115162, which is reachable but blocked from search engines. Xinuos marks this article against a retired product line. That refers to the product’s lifecycle, not to whether the advice still works — plenty of it still applies to running systems.

Next step

Need this fixed rather than explained?

Tell us the release, what the system runs and what it is doing. We will reply by email with what we would do next.

  • You deal with the people who do the work
  • No obligation, and no upgrade required before we will help
  • We tell you plainly if something is not worth doing

Send an enquiry

We reply by email. If a server is down, say so in the first line. You can also write to help@scoexpert.com.