Problem
How can I increase the performance of the High Throughput Filesystem (HTFS)?
Solution
Support Level Supplement (SLS) ODA403A provides a new
HT driver that can improve performance of the HTFS filesystem
under certain circumstances. See the attached cover letter
for further details.Dear SCO Customer,The enclosed Support Level Supplement (SLS) ODA403A, the HTFS
Performance Supplement, provides an enhanced High Throughput
Filesystem (HTFS). This enhancement is designed to increase total
disk performance in an environment in which there are a large
number of continuous small random accesses to the disk. SCO
has seen a significant filesystem performance increase on systems
using the new HTFS filesystem driver during server benchmark tests.
However, SCO does not believe that servers using the new driver
will see a significant increase in filesystem performance when
small continuous random disk accesses are not a common occurrence.INSTALLATION AND REMOVAL INSTRUCTIONSInstalling patches on SCO OpenServer 5.0.0 usually consists of two phases:
"Loading" and "Applying". The instructions that follow enable you to
both install the patch from distribution media or media image, as well
as configure the patch to be installed from a remote SCO OpenServer 5.0.0
system over a TCP/IP network.I. LOADING THE PATCH1. Log in as root.2. If you are installing this SLS from a media image, there is a file
called oda403a.Z. Uncompress this file with this command:# uncompress oda403a.ZCopy the file to the /tmp directory and name it VOL.000.000:
# cp oda403a /tmp/VOL.000.000If you are installing this SLS from floppy disk media, skip this step and proceed to step 3.
3. Execute the command:# scoadmin softwareor double click on the Software Manager icon on the desktop.
4. Pull down the "Software" menu and select "Patch Management-->Load Patch".
5. You will see the "Begin Load Patch" menu. Be sure the
local machine name is selected and choose "Continue".6. You will see the "Select Media" menu.
a. If you are loading this SLS from floppy disk media,
select the appropriate floppy disk drive and
choose "Continue". Proceed to step 7.b. If you are loading this SLS from a media image per step 2,
pull down the "Media Device" menu and select "Media Images",
then choose "Continue". You will then see the "Enter Image
Directory" menu. Enter /tmp and choose "OK".7. You will see the "Load Patch Preference" menu. Choose "Full".8. You will see the "Load Patch Progress" window. If the patch loads
successfully, you will see a "Message" window which states "Load
Patch complete". Choose "OK". You are then returned to the main
Software Manager window.9. To apply the patch now, continue with step 2 under section II,
"Applying the Patch". To exit the Software Manager now, select
"Exit" from the "Host" menu.II. APPLYING THE PATCH1. Log in as root. Execute the command:
# scoadmin softwareor double click on the Software Manager icon on the desktop.
2. Pull down the Software menu and select "Patch Management-->Apply Patch".
3. You will see the "Begin Apply Patch" menu. Be sure that the local
machine name is selected and choose "Continue".4. You will see the "Select Media" menu. The "Hard Disk" menu item
should already be selected. Choose "Continue".5. You will be presented with the "Select Patch-product to Apply" menu. Highlight the "HTFS Performance Patch" and then choose "Full" to continue.
6. You will see the "Apply Patch Progress" window as the system applies the patch.
7. You will see this message:NOTE: Application or rollback of this patch requires a kernel relink. If you are applying or rolling back several patches at this time, you may choose to defer the relink until the last patch application or rollback. Do you want to relink the kernel now? (y/n)
Enter "y" or "n" based on this message. Note that you will not be able to make use of the the patch until you relink the kernel, hence it is suggested that you answer "y" to this question.
8. If you chose "y" in number 7, the kernel will be relinked. In either case, you will then see
Press <RETURN> to continueAfter pressing the <RETURN> key, you will see the "Apply Patch Progress"
window, after which you will see a "Message" window stating "Apply Patch
Complete". Choose "OK" and you will be returned to the Software Manager's
main menu. Exit the Software Manager by choosing "Exit" from the
"Host" menu.9. Log in as root on tty01, and shut down the system:
# shutdown -g0 -yAfter shutting down and rebooting the machine, application of the patch is complete.
III. NOTES ON NETWORK INSTALLATIONTo install the patch on other SCO OpenServer 5.0.0 machines over the network,
first load the patch as in section I above on a designated installation
server. Then create the user "swadmin" on the installation server.When running the Software Manager on the system where the patch will be
installed, you will be prompted for the source location of the patch in
the "Begin Load Patch" window. Be sure to choose "from another host"
during this phase. You will need to provide the name of the installation
server, as well as the password of the "swadmin" user on the installation
server, to initiate the installation process.IV. PATCH REMOVALIf you ever want to remove the patch, take these steps:
1. Log in as root.2. Execute the command:# scoadmin softwareor double click on the Software Manager icon in the desktop.
4. Pull down the "Software" menu and select "Patch Management-->Rollback Patch".
5. You will see the "Begin Rollback Patch" menu, and be asked to select patched software to rollback. Select "SCO UNIX System V Operating System" and choose "Continue".
6. You will see the "Patch Selection" window. Make sure that the "HTFS Performance Patch" is selected, and choose "Continue".
7. You will see the "Confirm Selected Patches" window. Choose "Rollback" to confirm removal of the "HTFS Performance Patch".
8. You will see the "Rollback Progress" window, as the system performs the rollback of the patch.
9. You will see this message:NOTE: Application or rollback of this patch requires a kernel relink. If you are applying or rolling back several patches at this time, you may choose to defer the relink until the last patch application or rollback. Do you want to relink the kernel now? (y/n)
Enter "y" or "n" based on this message. Note that complete rollback of this patch requires a relink of the kernel to be complete, hence it is suggested that you answer "y" to this question, unless you are installing or removing other patches.
10. If you chose "y" in number 9, the kernel will be relinked. In either case, you will then see:
Press <RETURN> to continueAfter pressing the <RETURN> key, you will see the "Rollback Progress" window, after which a "Message" window stating "Rollback Patch Complete". Choose "OK" and you will be returned to the Software Manager's main menu. Exit the Software Manager by choosing "Exit" from the "Host" menu.
11. Log in as root on tty01, and shut down the system:
# shutdown -g0 -yAfter shutting down and rebooting the machine, rollback of the patch is complete.
12. To also unload the patch, making it no longer available to be applied,
follow the steps in this section. In step 4, choose:"Patch Management-->Unload Patch"instead of:"Patch Management-->Rollback Patch"Please note that patches must be rolled back in the reverse order in
which they were installed on a per-component basis. Hence, if the "HTFS
Performance Patch" is not the most recent patch applied to the UNIX
component of the product, you will have to rollback all patches applied
after the "HTFS Performance Patch" prior to rollback of the
"HTFS Performance Patch."If you have questions regarding this SLS, or the product on which it is installed, please contact your software supplier.
We appreciate your business.SCO Support Services