Problem
What is Support Level Supplement (SLS) OSS409A and how do I install it?
Solution
The attached cover letter describes the enhancements and corrections to known problems for SCO OpenServer Release 5.0.0 and 5.0.2 found in, and the installation procedure for, SLS OSS409A.
Dear SCO Customer,The enclosed Support Level Supplement (SLS) OSS409A, corrects a problem in the spx driver. The problem is that the spx driver assumes that there is always room on the downstream queue for a streams message block; if there is no room, the connection is forcibly disconnected. This assumption is incorrect and results in needless disconnections. This SLS was created for Informix-Online v7.10UD1.
INSTALLATION AND REMOVAL INSTRUCTIONSInstalling patches on SCO OpenServer 5.0.0 and 5.0.2 usually consists of
two phases: "Loading" and "Applying". The instructions that follow enable
you to both install the patch from distribution media or media image, as well
as configure the patch to be installed from a remote SCO OpenServer 5.0.0 or
5.0.2 system over a TCP/IP network.I. BEFORE LOADING THE PATCHUse the Software Manager to check which patches are currently on the system. If there is an ipx supplement (patch id rs.ipx200...), DO NOT install SLS OSS409A, as this SLS is included in the ipx supplement.
II. LOADING THE PATCHA. Log in as root.B. If you are installing this SLS from a media image, there is a file
called oss409a.Z. Uncompress this file with this command:# uncompress oss409a.ZCopy the file to the /tmp directory and name it VOL.000.000:
# cp oss409a /tmp/VOL.000.000If you are installing this SLS from floppy disk media, skip this step and proceed to step C.
C. Execute the command:# scoadmin softwareor double click on the Software Manager icon on the desktop.
D. Pull down the "Software" menu and select "Patch Management-->Load Patch".
E. You will see the "Begin Load Patch" menu. Be sure the
local machine name is selected and choose "Continue".F. You will see the "Select Media" menu.
1. If you are loading this SLS from floppy disk media,
select the appropriate floppy disk drive and
choose "Continue". Proceed to step G.2. If you are loading this SLS from a media image per step B,
pull down the "Media Device" menu and select "Media Images",
then choose "Continue". You will then see the "Enter Image
Directory" menu. Enter /tmp and choose "OK".G. You will see the "Load Patch Preference" menu. Choose "Full".H. You will see the "Load Patch Progress" window. If the patch loads
successfully, you will see a "Message" window which states "Load
Patch complete". Choose "OK". You are then returned to the main
Software Manager window.J. To apply the patch now, continue with step B under section III,
"Applying the Patch". To exit the Software Manager now, select
"Exit" from the "Host" menu.III. APPLYING THE PATCHA. Log in as root. Execute the command:
# scoadmin softwareor double click on the Software Manager icon on the desktop.
B. Pull down the Software menu and select "Patch Management-->Apply Patch".
C. You will see the "Begin Apply Patch" menu. Be sure that the local
machine name is selected and choose "Continue".D. You will see the "Select Media" menu. The "Hard Disk" menu item
should already be selected. Choose "Continue".E. You will be presented with the "Select Patch-product to Apply" menu. Highlight the "SPX Supplement" patch and then choose "Full" to continue.
F. You will see the "Apply Patch Progress" window as the system applies the patch.
G. You will see this message:NOTE: The SPX tunable parameter file has been replaced. Any changes made to this file should be reapplied. Backup copies of the replaced files can be found at: <backup directory spec>
H. Press return to continueJ. After pressing return, the kernel will be relinked automatically.
After the kernel has been relinked, you will see the "Apply Patch
Progress" window, after which you will see a "Message" window
stating "Apply Patch Complete". Choose "OK" and you will be
returned to the Software Manager's main menu. Exit the Software
Manager by choosing "Exit" from the "Host" menu.K. Log in as root on tty01, and shut down the system:
# shutdown -g0 -yAfter shutting down and rebooting the machine, application of the patch is complete.
IV. NOTES ON NETWORK INSTALLATIONTo install the patch on other SCO OpenServer 5.0.0 or 5.0.2 machines over
the network, first load the patch as in section II above on a designated
installation server. Then create the user "swadmin" on the installation
server.When running the Software Manager on the system where the patch will be
installed, you will be prompted for the source location of the patch in
the "Begin Load Patch" window. Be sure to choose "From Another Host"
during this phase. You will need to provide the name of the installation
server, as well as the password of the "swadmin" user on the installation
server, to initiate the installation process.V. PATCH REMOVALNOTE: Patches must be rolled back in the reverse order in which they
were installed on a per-component basis. Hence, if the "SPX Supplement"
patch is not the most recent patch applied to the UNIX component of
the product, you will have to rollback all patches applied after the
"SPX Supplement" patch prior to rollback of the "SPX Supplement"
patch.A. Log in as root.B. Execute the command:# scoadmin softwareor double click on the Software Manager icon in the desktop.
C. Pull down the "Software" menu and select "Patch Management-->Rollback Patch".
D. You will see the "Begin Rollback Patch" menu, and be asked to select patched software to rollback. Select "SCO UNIX System V Operating System" and choose "Continue".
E. You will see the "Patch Selection" window. Make sure that the "SPX Supplement" patch is selected, and choose "Continue".
F. You will see the "Confirm Selected Patches" window. Choose "Rollback" to confirm removal of the "SPX Supplement" patch.
G. You will see the "Rollback Progress" window, as the system performs the rollback of the patch.
H. You will see this message:NOTE: Application or rollback of this patch requires a kernel relink. If you are applying or rolling back several patches at this time, you may choose to defer the relink until the last patch application or rollback. Do you want to relink the kernel now? (y/n)
Enter "y" or "n" based on this message. Note that complete rollback of
this patch requires a relink of the kernel to be complete. Therefore,
it is suggested that you answer "y" to this question, unless you are
installing or removing other patches.J. If you chose "y", the kernel will be relinked. In either case, you will then see:
Press <RETURN> to continueAfter pressing the <RETURN> key, you will see the "Rollback Progress" window, after which a "Message" window stating "Rollback Patch Complete". Choose "OK" and you will be returned to the Software Manager's main menu. Exit the Software Manager by choosing "Exit" from the "Host" menu.
K. Log in as root on tty01, and shut down the system:
# shutdown -g0 -yAfter shutting down and rebooting the machine, rollback of the patch is complete.
L. To also unload the patch, making it no longer available to be applied,
follow the steps in this section. In step C, choose:"Patch Management-->Unload Patch"instead of:"Patch Management-->Rollback Patch"If you have questions regarding this SLS, or the product on which it is installed, please contact your software supplier.
We appreciate your business.SCO Support Services