Problem
What is Support Level Supplement (SLS) OSS436A and how do I install it?
Solution
The attached cover letter describes the enhancements and corrections to known problems for SCO OpenServer Release 5.0.0 found in, and the installation procedure for, SLS OSS436A.
Dear SCO Customer,The enclosed Support Level Supplement (SLS) OSS436A, the Kernel Error Path Supplement, corrects a known problem in a kernel error path. This problem could cause a regular user to inappropriately gain root access to the system.
SLS OSS436A should be installed only on these releases:
SCO OpenServer Enterprise System Release 5.0.0, 5.0.2 SCO OpenServer Desktop System Release 5.0.0, 5.0.2 SCO OpenServer Host System Release 5.0.0, 5.0.2 SCO Internet FastStart 1.0.0
INSTALLATION AND REMOVAL INSTRUCTIONSInstalling patches on SCO OpenServer 5 usually consists of two phases:
"Loading" and "Applying". The instructions that follow enable you to
both install the patch from distribution media or media image, as well
as configure the patch to be installed from a remote SCO OpenServer 5
system over a TCP/IP network.I. LOADING THE PATCH1. Log in as root.2. If you are installing this SLS from floppy disk media, skip this step and proceed to step 3.
If you are installing this SLS from a media image, there is a file
called oss436a.Z. Uncompress this file with this command:# uncompress oss436a.ZCopy the file to the /tmp directory and name it VOL.000.000:
# cp oss436a /tmp/VOL.000.0003. Execute the command:# scoadmin softwareor double click on the Software Manager icon on the desktop.
4. Pull down the "Software" menu and select "Patch Management-->Load Patch".
5. You will see the "Begin Load Patch" menu. Be sure the
local machine name is selected and choose "Continue".6. You will see the "Select Media" menu.
a. If you are loading this SLS from floppy disk media,
select the appropriate floppy disk drive and
choose "Continue". Proceed to step 7.b. If you are loading this SLS from a media image per step 2,
pull down the "Media Device" menu and select "Media Images",
then choose "Continue". You will then see the "Enter Image
Directory" menu. Enter /tmp and choose "OK".7. You will see the "Load Patch Preference" menu. Choose "Full".8. You will see the "Load Patch Progress" window. If the patch loads
successfully, you will see a "Message" window which states "Load
Patch complete". Choose "OK". You are then returned to the main
Software Manager window.9. To apply the patch now, continue with step 2 under section II,
"Applying the Patch". To exit the Software Manager now, select
"Exit" from the "Host" menu.II. APPLYING THE PATCH1. Log in as root. Execute the command:
# scoadmin softwareor double click on the Software Manager icon on the desktop.
2. Pull down the Software menu and select "Patch Management-->Apply Patch".
3. You will see the "Begin Apply Patch" menu. Be sure that the local
machine name is selected and choose "Continue".4. You will see the "Select Media" menu. The "Hard Disk" menu item
should already be selected. Choose "Continue".5. You will be presented with the "Select Patch-product to Apply" menu. Highlight the "Kernel Error Path Supplement" patch and then choose "Full" to continue.
6. You will see the "Apply Patch Progress" window as the system applies the patch.
7. You will see the following messages:
The UNIX Operating System will now be rebuilt.
This will take a few minutes. Please wait.Root for this system build is /Backing up unix to unix.old Installing new unix on the boot file system Setting up new kernel environment
Press <Enter> to continue.8. After pressing <Enter>, you will see the "Apply Patch Progress"
window, after which you will see a "Message" window stating "Apply
Patch Complete". Choose "OK" and you will be returned to the Software
Manager's main menu. Exit the Software Manager by choosing "Exit"
from the "Host" menu.9. Log in as root on tty01, and shut down the system:
# shutdown -g0 -yAfter shutting down and rebooting the machine, application of the patch is complete.
III. NOTES ON NETWORK INSTALLATIONTo install the patch on other SCO OpenServer 5 machines over the
network, first load the patch as in section I above on a designated
installation server. Then create the user "swadmin" on the installation
server.When running the Software Manager on the system where the patch will be
installed, you will be prompted for the source location of the patch in
the "Begin Load Patch" window. Be sure to choose "From Another Host"
during this phase. You will need to provide the name of the installation
server, as well as the password of the "swadmin" user on the installation
server, to initiate the installation process.IV. PATCH REMOVALNOTE: Patches must be rolled back in the reverse order in which they
were installed on a per-component basis. Hence, if the "Kernel Error
Path Supplement" patch is not the most recent patch applied to the UNIX
component of the product, you will have to rollback all patches applied
after the "Kernel Error Path Supplement" patch prior to rollback of the
"Kernel Error Path Supplement" patch.To remove the patch, take these steps:
1. Log in as root.2. Execute the command:# scoadmin softwareor double click on the Software Manager icon in the desktop.
3. Pull down the "Software" menu and select "Patch Management-->Rollback Patch".
4. You will see the "Begin Rollback Patch" menu, and be asked to select patched software to rollback. Select "SCO UNIX System V Operating System" and choose "Continue".
5. You will see the "Patch Selection" window. Make sure that the "Kernel Error Path Supplement" patch is selected, and choose "Continue".
6. You will see the "Confirm Selected Patches" window. Choose "Rollback" to confirm removal of the "Kernel Error Path Supplement" patch.
7. You will see the "Rollback Progress" window, as the system performs the rollback of the patch.
8. You will see an information window displaying the message:
NOTE: During this rollback, the link kit will be updated. Afterwards
you must relink your kernel and reboot your machine in order
to make this rollback effectivePress <Enter> to continue:9. After pressing <Enter> you will see the "Rollback Progress" window, after which a "Message" window stating "Rollback Patch Complete". Choose "OK" and you will be returned to the Software Manager's main menu. Exit the Software Manager by choosing "Exit" from the "Host" menu.
10. Log in as root and relink the kernel:
# cd /etc/conf/cf.d
# ./link_unix -y11. Log in as root on tty01, and shut down the system:
# shutdown -g0 -yAfter shutting down and rebooting the machine, rollback of the patch is complete.
12. To also unload the patch, making it no longer available to be applied,
follow the steps in this section. In step 3, choose:"Patch Management-->Unload Patch"instead of:"Patch Management-->Rollback Patch"If you have questions regarding this SLS, or the product on which it is installed, please contact your software supplier.
We appreciate your business.SCO Support Services