Technical article 105494

What is Support Level Supplement (SLS) OSS451B?

OpenServer 5.0.0OpenServer 5.0.2

Written · Last revised

Problem

When I try to install SCO OpenServer Release 5 on a system with an EIDE hard drive that is greater than 2GB, the installation fails in one of the following ways:

-  Unable to detect ROOT filesystem.
-  An error message "NOTICE: ram: No space on device on
   device 31/50" occurs after completing the screen with the
   time zone.
-  An error message "Exit value: 1 Status Value: 256" from IQM
   is seen.
-  Filesystems that are greater than 2 gigabytes (GB) cannot be
   checked with "fsck" and may not be fully usable.
-  The bad track table overflows when the bad tracking option is
   set and the size of IDE hard drive exceeds 2GB.

Solution

Support Level Supplement (SLS) OSS451B contains a replacement Western Digital ATAPI driver for SCO OpenServer Release 5.0.0, 5.0.2 and SCO Internet FastStart Release 1.0.0, 1.1.0.

This corrects problems that occur when installing SCO OpenServer on EIDE hard disks with a capacity greater than 2 Gigabytes (GB), using an IDE (ATAPI) CD-ROM or using other installation devices.

The cover letter for SLS OSS451B follows.

See also

TA107233 "How can I download software supplements from SCO?"

Dear SCO Customer,

The enclosed Support Level Supplement (SLS) OSS451B, WDATAPI BTLD for EIDE, contains a replacement Western Digital ATAPI driver for SCO OpenServer Release 5.0.0, 5.0.2 and SCO Internet FastStart Release 1.0.0, 1.1.0.

This corrects problems installing SCO OpenServer on EIDE hard disks with a capacity greater than 2 Gigabytes (GB), using an IDE (ATAPI) CD-ROM or other installation devices. When trying to install, the installation fails in one of the following ways:

-  Unable to detect ROOT filesystem.
-  An error message "NOTICE: ram: No space on device on device 31/50"
   occurs after completing the screen with the time zone.
-  An error message "Exit value: 1 Status Value: 256" from IQM is seen.
-  Filesystems that are greater than 2 gigabytes (GB) cannot be checked
   with "fsck" and may not be fully usable.
-  The bad track table overflows when the bad tracking option is
   set and the size of IDE hard drive exceeds 2GB.
At installation time, do the following:

1. Follow normal SCO BTLD instructions as documented in the AHS 5.02 Release Notes or in other SCO documentation. Choose the package "wd" Note the information in Step 2 below, which is specific to SLS OSS451B. This BTLD replaces the wd driver in AHS 5.02 or in SCO OpenServer 5.0.0 or 5.0.2.

2. Do NOT Scan for bad tracks as a new "badtrk" utility, which is included
   in this SLS, has not been installed yet.  If you have already attempted
   to scan for bad tracks, and the hard drive is greater than 2GB, you will
   need to delete the entries in the Current Bad Track Table, using the
   procedure below. A badtrk scan can be done after installation.  To
   delete the badtrk entries:
Select option six (6),  Delete All entries from
Current Bad Track Table.  Enter 'q' to quit and then
press <Enter> to accept the default value for the bad
track space allocation.  When prompted: "Do you wish
to update this device with the new table? (y/n)",
enter 'y' to update device with new table.  When
prompted: "Do you want to attempt to salvage
...(y/n)", enter 'n'.

3. Proceed with the installation using standard BTLD procedures.

To install this SLS after installation, do the following:

Note: If you have SCO OpenServer Release 5.0.0, you should install Release Supplement 5.0.0d before installing this SLS.

1. Insert the SLS OSS451B floppy diskette in the primary floppy drive.

2. Type "mount /dev/fd0135ds18 /mnt" for a 3.5 inch 1.44MB drive.

3. Type "btldinstall /mnt".

4. A message will appear stating that the kernel must be relinked for the changes to be effective. To do so, type:

cd /etc/conf/cf.d
./link_unix -y
5. Reboot the system.

If you have questions regarding this SLS, or the product on which it is installed, please contact your software supplier.

We appreciate your business.
SCO Support Services

From the Xinuos technical article database, record 105494. Reproduced with permission. The original is at www.sco.com/ta/105494, which is reachable but blocked from search engines. Xinuos marks this article against a retired product line. That refers to the product’s lifecycle, not to whether the advice still works — plenty of it still applies to running systems.

Next step

Need this fixed rather than explained?

Tell us the release, what the system runs and what it is doing. We will reply by email with what we would do next.

  • You deal with the people who do the work
  • No obligation, and no upgrade required before we will help
  • We tell you plainly if something is not worth doing

Send an enquiry

We reply by email. If a server is down, say so in the first line. You can also write to help@scoexpert.com.