Problem

What is Support Level Supplement (SLS) OSS452A, the Trap F Supplement, and how do I install it?

Solution

The attached cover letter describes the enhancements and corrections to known problems for SCO OpenServer Release 5.0 and Internet FastStart Release 1.* found in, and the installation procedure for, SLS OSS452A.

Dear SCO Customer,

The enclosed Support Level Supplement (SLS) OSS452A, prevents a panic with the panic message:

PANIC: k_trap   kernel mode trap type 0x0000000F
which is known to occur on Pentium Pro machines, most notably while printing
to a parallel port.  It is most frequently associated with running SCO
OpenServer 5.0 on a single CPU without SCO SMP on a machine containing an
APIC chipset and multiple CPUs.  At this point, the occurrence of a trap F
can be considered to be a spurious event of no special significance to the
operating system.
This patch resolves the issue by acting on an occurrence of a trap F event
in a manner other than panicking the system.  When the patch is applied,
the response of the kernel to a trap F becomes tunable.  The description below
of the tunability is appended to the file /etc/conf/pack.d/kernel/space.c.
By default, the tunable variable trapf_action is set to 2:
/*                                                 TRAP_F_PATCH
 * The setting of trapf_action defines the behavior in the
 * event of a the kernel receiving a Trap F. Note that this
 * should never happen, and is probably the result of a
 * hardware problem with your system. Appropriate action
 * should be taken to trace and rectify the fault. The
 * following actions may be taken on receipt of a Trap F:
 *
 *      trapf_action     action
 *      ----------------------------------
 *           0           PANIC the kernel
 *           1           consume the Trap F silently
 *           2           report the error first time only
 *           3           report the error every time
 */
int trapf_action = 2;                           /* TRAP_F_PATCH */
If desired, the value of trapf_action may be modified to take on the values
0, 1, or 3.  Relink the kernel and reboot for the changes to take effect.
Note: Instead of applying this patch, a BIOS fix from the BIOS manufacturer
      may be obtained.  This is most highly recommended, as it will prevent
      these spurious trap F events from occurring.  Also, in the upcoming
      release of SCO OpenServer 5, the response of the kernel to a trap F
      will not be tunable, and will be as if trapf_action is set to the
      value 3.
RELEASE INFORMATION

SLS OSS452A is intended for use on these products:

SCO OpenServer Enterprise System Release 5.0.0, 5.0.2 SCO OpenServer Desktop System Release 5.0.0, 5.0.2 SCO OpenServer Host System Release 5.0.0, 5.0.2 SCO Internet FastStart Release 1.0.0, 1.1.0

INSTALLATION AND REMOVAL INSTRUCTIONS
Installing patches on SCO OpenServer 5.0.x usually consists of two phases:
"Loading" and "Applying".  The instructions that follow enable you to both
install the patch from distribution media or media image, as well as
configure the patch to be installed from a remote SCO OpenServer 5.0.x
system over a TCP/IP network.
I. LOADING THE PATCH
1. Log in as root.
2. If you are installing this SLS from a media image, there is a file
   called oss452a.Z.  Uncompress this file with this command:
# uncompress oss452a.Z

Copy the file to the /tmp directory and name it VOL.000.000:

# cp oss452a /tmp/VOL.000.000

If you are installing this SLS from floppy disk media, skip this step and proceed to step 3.

3. Execute the command:
# scoadmin software

or double click on the Software Manager icon on the desktop.

4. Pull down the "Software" menu and select "Patch Management-->Load Patch".

5. You will see the "Begin Load Patch" menu.  Be sure the
   local machine name is selected and choose "Continue".

6. You will see the "Select Media" menu.

a. If you are loading this SLS from floppy disk media,
   select the appropriate floppy disk drive and
   choose "Continue".  Proceed to step 7.
b. If you are loading this SLS from a media image per step 2,
   pull down the "Media Device" menu and select "Media Images",
   then choose "Continue".  You will then see the "Enter Image
   Directory" menu.  Enter /tmp and choose "OK".
7. You will see the "Load Patch Preference" menu.  Choose "Full".
8. You will see the "Load Patch Progress" window.  If the patch loads
   successfully, you will see a "Message" window that states "Load
   Patch complete".  Choose "OK".  You are then returned to the main
   Software Manager window.
9. To apply the patch now, continue with step 2 under section II,
   "Applying the Patch".  To exit the Software Manager now, select
   "Exit" from the "Host" menu.
II. APPLYING THE PATCH

1. Log in as root. Execute the command:

# scoadmin software

or double click on the Software Manager icon on the desktop.

2. Pull down the Software menu and select "Patch Management-->Apply Patch".

3. You will see the "Begin Apply Patch" menu.  Be sure that the local
   machine name is selected and choose "Continue".
4. You will see the "Select Media" menu. The "Hard Disk" menu item
   should already be selected.  Choose "Continue".

5. You will be presented with the "Select Patch-product to Apply" menu. Highlight the "Streams Lock Timeout and Protocol Data Supplement oss452a" patch and then choose "Full" to continue.

6. You will see the "Apply Patch Progress" window as the system applies the patch.

7. You will see an information window displaying the message:

During this apply patch, the kernel was relinked. You must reboot your system to make this kernel effective.

Click on "OK".
8. You will see a "Message" window stating "Apply Patch Complete".  Choose "OK"
   and you will be returned to the Software Manager's main menu.  Exit the
   Software Manager by choosing "Exit" from the "Host" menu.

9. Log in as root on tty01, and shut down the system:

# shutdown -g0 -y

After shutting down and rebooting the machine, application of the patch is complete.

III. NOTES ON NETWORK INSTALLATION
To install the patch on other SCO OpenServer 5.0.* machines over the network,
first load the patch as in section I above on a designated installation
server.  Then create the user "swadmin" on the installation server.
When running the Software Manager on the system where the patch will be
installed, you will be prompted for the source location of the patch in
the "Begin Load Patch" window.  Be sure to choose "from another host"
during this phase.  You will need to provide the name of the installation
server, as well as the password of the "swadmin" user on the installation
server, to initiate the installation process.
IV. PATCH REMOVAL
NOTE: Patches must be rolled back in the reverse order in which they were
installed on a per-component basis.  Hence, if the "Trap F Supplement oss452a"
patch is not the most recent patch applied to the UNIX component of the
product, you will have to rollback all patches applied after the "Trap F
Supplement oss452a" patch prior to rollback of the "Trap F Supplement
oss452a" patch.

If you want to remove the patch, take these steps:

1. Log in as root.
2. Execute the command:
# scoadmin software

or double click on the Software Manager icon in the desktop.

3. Pull down the "Software" menu and select "Patch Management-->Rollback Patch".

4. You will see the "Begin Rollback Patch" menu, and be asked to select patched software to rollback. Select "SCO UNIX System V Operating System" and choose "Continue".

5. You will see the "Patch Selection" window. Make sure that the "Trap F Supplement oss452a" patch is selected, and choose "Continue".

6. You will see the "Confirm Selected Patches" window. Choose "Rollback" to confirm removal of the "Trap F Supplement oss452a" patch.

7. You will see the "Rollback Progress" window, as the system performs the rollback of the patch.

8. You will see an information window displaying the message:

NOTE: During this rollback, the link kit wll be updated. Afterwards
      you must relink your kernel and reboot your machine in order
      to make this rollback effective.
Press return to continue:
9. After pressing the <RETURN> key, you will see the "Rollback Progress"
   window, after which a "Message" window stating "Rollback Patch Complete"
   appears.  Choose "OK" and you will be returned to the Software Manager's
   main menu. Exit the Software Manager by choosing "Exit" from the "Host"
   menu.

10. Log in as root and relink the kernel:

# cd /etc/conf/cf.d
# ./link_unix -y

11. Log in as root on tty01, and shut down the system:

# shutdown -g0 -y

After shutting down and rebooting the machine, rollback of the patch is complete.

12. To also unload the patch, making it no longer available to be applied,
    follow the steps in this section.  In step 3, choose:
"Patch Management-->Unload Patch"
instead of:
"Patch Management-->Rollback Patch"

If you have questions regarding this SLS, or the product on which it is installed, please contact your software supplier.

We appreciate your business.
SCO Support Services

From the Xinuos technical article database, record 105500. Reproduced with permission. The original is at www.sco.com/ta/105500, which is reachable but blocked from search engines. Xinuos marks this article against a retired product line. That refers to the product’s lifecycle, not to whether the advice still works — plenty of it still applies to running systems.

Next step

Need this fixed rather than explained?

Tell us the release, what the system runs and what it is doing. We will reply by email with what we would do next.

  • You deal with the people who do the work
  • No obligation, and no upgrade required before we will help
  • We tell you plainly if something is not worth doing

Send an enquiry

We reply by email. If a server is down, say so in the first line. You can also write to help@scoexpert.com.