Technical article 118212

What is Support Level Supplement (SLS) OSS648C, the Processor Supplement for OpenServer 5.0.6?

OpenServer 5.0.6

Written · Last revised

Problem

What is SLS OSS648C, the Processor Supplement for OpenServer 5.0.6?

Solution

SLS OSS648C, the Processor Supplement for OpenServer 5.0.6, addresses the following problems and changes:

1) On some multiprocessor systems the driver for a PCI card with a PCI-to-PCI bridge onboard was unable to register its interrupt.

Note: The following fixes were also included in SLS OSS648B:

2) On a multiprocessor system PCI interrupt sharing was failing when
   one or more of the drivers sharing an interrupt was able to handle
   the interrupt on any processor.  Symptoms of this problem included
   spurious and lost interrupts.

Note: The following fixes were also included in SLS OSS648A:

3) On a multiprocessor system with fast processors, the auxiliary
   processor was timing out with the error message "WARNING: CPU2 did
   not finish boot code".  This solution  only applies if SMP is
   installed.

4) A Pentium 4 processor was running with a 50% duty cycle.

5) Pentium 4 processor thermal management is initialized.

6) Adds processor recognition for newer Pentium III models, and Intel NetBurst microarchitecture Pentium 4 and Intel Xeon processors.

7) Adds support for Pentium 4 machine check handling.

8) Adds newer Pentium III and Pentium 4 processors and Pentium 4 Model Specific Registers to the "hw -v -rcpu" command.

9) Adds enhancements for displaying Model Specific Registers for the "hw -v -rcpu" command.

10) Adds enhancements and fixes for the "hw -v -rpci" command.

See the attached cover letter for more information, including installation instructions.

------------------------------------------------------------------------
Dear SCO Customer,

Support Level Supplement (SLS) OSS648C, the Processor and SMP Supplement for OpenServer 5.0.6, addresses the following problems and changes:

1)  On some multiprocessor systems the driver for a PCI card with a
    PCI-to-PCI bridge onboard was unable to register its interrupt.

Note: The following fixes were also included in SLS OSS648B:

2)  On a multiprocessor system PCI interrupt sharing was failing when one
    or more of the drivers sharing an interrupt was able to handle the
    interrupt on any processor.  Symptoms of this problem included
    spurious and lost interrupts.

Note: The following fixes were also included in SLS OSS648A:

3)  On a multiprocessor system with fast processors, the auxiliary processor
    was timing out with the error message "WARNING: CPU2 did not finish boot
    code".  This solution  only applies if SMP is installed.
4)  A Pentium 4 processor was running with a 50% duty cycle.
5)  Pentium 4 processor thermal management is initialized.
6)  Adds processor recognition for newer Pentium III models, and Intel NetBurst
    microarchitecture Pentium 4 and Intel Xeon processors.
7)  Adds support for Pentium 4 machine check handling.
8)  Adds newer Pentium III and Pentium 4 processors and Pentium 4 Model Specific
    Registers to the "hw -v -rcpu" command.
9)  Adds enhancements for displaying Model Specific Registers for the
    "hw -v -rcpu" command.

10) Adds enhancements and fixes for the "hw -v -rpci" command.

SLS OSS648C updates these files:
        /etc/conf/pack.d/apic/Driver.o
        /etc/conf/pack.d/apic/space.c
        /etc/conf/pack.d/crllry/Driver.a
	/etc/conf/pack.d/crllry/space.c
        /etc/conf/pack.d/mpsw/Driver.o
        /etc/conf/pack.d/kernel/os.a
        /etc/conf/pack.d/pci/Driver.o
        /etc/hw
Software Notes and Recommendations
----------------------------------
SLS OSS648C should only be installed on:

SCO OpenServer Release 5.0.6 with Release Supplement 506A (rs506a)

WARNING: Do not run OpenServer on systems with the Intel NetBurst
         microarchitecture Pentium 4 or Intel Xeon processor without
         Release Supplement 506A.  Doing so might damage your hardware.
         For further information, see the "Release and Installation Notes"
         for "Release Supplement 5.0.6A for OpenServer 5".  This document
         is available from:
https://ftp.scoexpert.com/openserver5/rs506a/rs506a.txt
Installation Instructions
-------------------------

1. Download the OSS648C media image file from:

	     https://ftp.scoexpert.com/openserver5/oss648c

Place the file in the /tmp directory, and rename the file by typing the command:

mv /tmp/oss648c /tmp/VOL.000.000

2. Run the Software Manager with the command:

# scoadmin software

or double-click on the Software Manager icon in the desktop.

3. Pull down the "Software" menu and select "Install New".

4. When prompted for the host from which to install, choose the local machine and then "Continue".

5. In the "Select Media" menu, pull down the "Media Device" menu.  Select
   "Media Images", then choose "Continue".

6. When prompted for the "Image Directory", enter "/tmp" (or the directory where you placed the VOL file in step 1) and choose "OK".

7. When prompted to select software to install, make sure that the "OSS648A"
   entry is highlighted.  Choose "Install".
8. Installation of SLS OSS648C is now complete.  To exit the Software Manager,
   select "Exit" from the "Host" menu.
9. A kernel relink occurred during this process and it will be necessary to
   reboot the server for the supplement to take effect.
Removal Instructions
--------------------

Note: Patches must be rolled back in the reverse order in which they were installed on a per-component basis.

To remove SLS OSS648C from SCO OpenServer 5.0.6, follow these steps:

1. Log in as root.
2. Execute the command:
# scoadmin software

or double-click on the Software Manager icon in the desktop.

3. Highlight "OSS648C: Processor Supplement for OpenServer 5.0.6".

4. Pull down the "Software" menu and select "Remove Software".

5. Once the removal finishes, quit the Software Manager.  Removal of
   SLS OSS648C is now complete.

6. A kernel relink occurred during this process and it will be necessary in order to reboot the server.

If you have questions regarding this SLS, or the product on which it is installed, please contact your software supplier.

From the Xinuos technical article database, record 118212. Reproduced with permission. The original is at www.sco.com/ta/118212, which is reachable but blocked from search engines.

Next step

Need this fixed rather than explained?

Tell us the release, what the system runs and what it is doing. We will reply by email with what we would do next.

  • You deal with the people who do the work
  • No obligation, and no upgrade required before we will help
  • We tell you plainly if something is not worth doing

Send an enquiry