Technical article 104779

What is the installation procedure for the Olivetti SNX200/RS?

OpenServer 5.0.0

Written · Last revised

Problem

What is the procedure to install the Olivetti SNX200/RS?

Solution

The SNX200 is a PCI/EISA machine with a C-BUS II system bus. It may have either one or two Pentium CPU cards. The base unit can accommodate up to six 'hot swap' hard disk units which will normally be attached to a DPT 3224 RAID controller. The machine may also include an Adaptec 'Alad' card (AIC 7850) to provide a separate SCSI channel for SCSI tapes and CD-ROMs.

The Starter Kit for the SNX200 includes two disks entitled
DPT/OLIVETTI PCI Storage Manager Utilities. The Storage Manager
utility allows users to check their SCSI hardware configuration
 and allows for disk arrays to be configured.  Before the SNX200/RS
 is installed for the first time, the 'Initial System Installation'
procedure should be performed as described in the PM3224 User's
Guide. During this procedure, you will be asked to select the
Operating System you will eventually install. Choosing SCO UNIX
 will cause a 'Supplemental Utility' disk to be created. This disk
 is a BTLD for the DPT PCI raid controller. It also includes an
 error logging utility for the RAID controller.
The Operating Systems Installation chapter of the PM3224 User's
Guide contains a section which describes the process for installing
SCO UNIX Version 4.2 (and SCO Open Desktop 3.0) in more detail.
 However, it states that the installation media and the boot device
 must both be attached to the same SCSI controller.  This is not
 the case, providing the correct boot string is given during
 installation.

To install from a CD-ROM attached to the Alad controller with the hard disk attached to the DPT controller, the following boot string should be used:

defbootstr disable=dpt link="alad dptraid" Sdsk=dptr(0,0,0)

You will be prompted for two separate BTLD disks. The Alad BTLD is in the Starter Kit entitled 'SNX200 RS PCI to SCSI Device Drivers 2/2'. The dptraid BTLD is the Supplemental Utility disk created by Storage Manager. You may still need to alter the default device type for the installation media. After the IQM phase of the installation, before any data is extracted from the CD-ROM, this message will occur:

'WARNING: Multiple SCSI host adapters detected'

This can be safely ignored. During the installation, follow the prompts for inserting the two BTLD disks as normal.

  Single processor versus multi-processor systems
  ===============================================
The Starter Kit also contains a booklet called 'Support for
 Operating Systems', as well as a Corollary SLS and a Corollary
 EFS. The booklet describes how to install the Corollary SLS for
 a single processor system and MPX 3.0. It also describes how to
 install the Corollary EFS and Corollary SLS for multi-processor
 systems. All of these products should be installed in single-user
 mode.

Before the installation of the Corollary SLS, it is possible that the amount of memory displayed during boot time by UNIX is incorrect. This problem is rectified by the SLS.

The SNX200/RS has a Cirrus Logic GD5422 chip on the motherboard. A problem with MPX restricts you to running standard VGA graphics. SCO's MPX Performance Supplement (Support Level Supplement SLS UOD393C or later) resolves this problem. This supplement should be custom installed in single-user mode.

  Installing SCO OpenServer Release 5.0.0
  =======================================
SCO OpenServer Release 5.0.0 includes an Alad driver and a DPT
 raid driver.  However, the DPT raid driver is not a PCI version
 and it can only be used to install disks which are not in a RAID
 configuration. A DPT PCI driver is scheduled to be included in a
 future release of the SCO Advanced Hardware Supplement (AHS).
 The dptraid driver created by the Storage Manager Utility
 cannot be used with SCO OpenServer Release 5.0.0.

Support for Corollary C-BUS II is included in SCO OpenServer Release 5.0.0. However, ECC is not currently supported. Invoking ECC with the 'mkdev eccd' command will cause the SNX200 to hang or panic. This is scheduled to be fixed in a future release.

From the Xinuos technical article database, record 104779. Reproduced with permission. The original is at www.sco.com/ta/104779, which is reachable but blocked from search engines. Xinuos marks this article against a retired product line. That refers to the product’s lifecycle, not to whether the advice still works — plenty of it still applies to running systems.

Next step

Need this fixed rather than explained?

Tell us the release, what the system runs and what it is doing. We will reply by email with what we would do next.

  • You deal with the people who do the work
  • No obligation, and no upgrade required before we will help
  • We tell you plainly if something is not worth doing

Send an enquiry