Technical article 105617

What is the Release Supplement for SCO OpenServer 5.0.4, RS504A?

OpenServer 5.0.4

Written · Last revised

Problem

What is contained in Release Supplement RS504A, the first Release Supplement for SCO OpenServer Release 5.0.4?

Solution

The attached cover letter describes the enhancements and corrections to known problems for SCO OpenServer Release 5.0.4 found in, and the installation procedure for, RS504A.

Dear SCO Customer,
The enclosed supplement, RS504A, the first Release Supplement for SCO
OpenServer Release 5.0.4, corrects some improper permissions on system
directories on an SCO OpenServer Release 5.0.4 system.  These improper
permissions make the directories vulnerable to possible tampering.  The
corrections are automatically made upon installation of the supplement;
no further steps are necessary.
WHO SHOULD INSTALL THIS SUPPLEMENT?

This Release Supplement does _not_ need to be installed on OpenServer 5.0.4 systems if, when invoking the SCO Software Manager (from the graphical desktop or by typing "scoadmin software" from a character-based session) it shows that the Release Supplement for SCO OpenServer Release 5.0.4 (ver rs.Unix504.0.1.a) is installed on the system.

If you have not yet installed SCO OpenServer Release 5.0.4, and wish to
find out whether the Release Supplement will be required, refer to the
9-digit part number on the SCO OpenServer CD-ROM.  The CD-ROM with part
number:
200-920-103

does _not_ require separate installation of the supplement.

However, a CD-ROM with the part number:

200-920-102

_does_ require separate installation of the supplement.

Note: In the instructions below, please note that for this particular
supplement, either "Installing" or "Loading" the supplement causes the
patch to take effect on the local system.  This is not generally true;
usually only Installing the patch causes it to take effect on your system.
Note: The designation "RS504A" is used to identify the patch to SCO
Services and customers.  However, it is not an official part of the
"patch ID" (version rs.Unix504.0.1.a).  Hence, the label RS504A will
not appear in the Software Manager after Installing/Loading the patch.
Use the patch ID, rs.Unix504.0.1.a, as confirmation that the patch is
installed.  For the vast majority of SCO Supplements, the SLS or RS
number (for example, OSS452A) is part of the patch description.

(rest of text deleted - See NOTE section above)

From the Xinuos technical article database, record 105617. Reproduced with permission. The original is at www.sco.com/ta/105617, which is reachable but blocked from search engines. Xinuos marks this article against a retired product line. That refers to the product’s lifecycle, not to whether the advice still works — plenty of it still applies to running systems.

Next step

Need this fixed rather than explained?

Tell us the release, what the system runs and what it is doing. We will reply by email with what we would do next.

  • You deal with the people who do the work
  • No obligation, and no upgrade required before we will help
  • We tell you plainly if something is not worth doing

Send an enquiry

We reply by email. If a server is down, say so in the first line. You can also write to help@scoexpert.com.