Technical article 110887

What issues are addressed by SLS APP618A, the SCO ARCserve/Open 2.2.0 Maintenance Supplement for SCO OpenServer 5?

OpenServer 5.0.2OpenServer 5.0.4OpenServer 5.0.5

Written · Last revised

Problem

What issues are addressed by Support Level Supplement (SLS) APP618A, the SCO ARCserve/Open 2.2.0 Maintenance Supplement for SCO OpenServer 5?

Solution

SLS APP618A includes fixes for known problems, including Year 2000 issues, and adds support for new tape devices.

SLS APP618A supersedes APP607A, the Year 2000 Supplement for SCO
ARCserve/Open 2.2.0k on SCO OpenServer and the SCO ARCserve/Open
2.2.0 Maintenance Supplement Release 1.1.0.  Both of these
supplements should be removed prior to installing SLS APP618A.

See the attached cover letter for a list of included fixes, a list of supported tape devices, and installation instructions.

Dear SCO Customer,

Support Level Supplement (SLS) APP618A, the SCO ARCserve/Open 2.2.0 Maintenance Supplement for SCO ARCserve/Open running on SCO OpenServer 5, includes fixes for known problems, including Year 2000 issues, and adds support for new tape devices. The list of fixes, as well as the list of tape devices, are located in the "Problems Fixed" section.

SLS APP618A should only be installed on systems running SCO ARCserve/Open Release 2.2.0k with SCO OpenServer Release 5.0.2, 5.0.4, or 5.0.5.

SLS APP618A supersedes APP607A, the Year 2000 Supplement for SCO ARCserve/Open
2.2.0k on SCO OpenServer and the SCO ARCserve/Open 2.2.0 Maintenance Supplement
Release 1.1.0.  Both of these supplements should be removed prior to installing
APP618A.
Problems Fixed
--------------

The following Year 2000 problems are addressed by this SLS:

1.  Reports generated using the Report Manager GUI report all Y2K dates
    incorrectly.

When a report is generated, dates that are year 2000 or greater are incorrectly displayed as 100 (year 2000), 101 (year 2001), 102 (year 2002), and so on. Depending on the version of the operating system on which SCO ARCserve/Open is being run, the year 2000 may also be displayed as a two-digit number of 69 or greater.

The correct format for the dates should be 00 (year 2000), 01 (year 2001), 02 (year 2002), and so on.

2.  Output from as_qmgr (command line) reports Y2K dates incorrectly.
When you run as_qmgr to list the jobs in the queue, or to change
the date in which a job will run, year 2000 or greater dates are
displayed incorrectly.  They are displayed as described above in
problem 1.
3.  Autopilot labels a tape incorrectly when the year is 2000 or greater.
When autopilot labels a tape, it includes the current date as part
of the label name.  When the year is 2000 or greater, the date used
on the label is incorrect.  It uses dates as described above in
problem 1.
4.  Using the format tapes option in the Device Manager GUI to format
    a tape in a tape library, displays incorrect expiration dates if
    the year is in the year 2000 or greater.

If you are using a changer or tape library, and choose to format a tape, the default expiration date is not displayed correctly in the year 2000 or greater. This date is displayed as described above in problem 1.

In addition, SLS APP618A includes the following changes:

1.  Corrects the Import/Export for the Tandberg 1000 series changers
    (TDS 1210, TDS 1420, TDS 1440).
2.  Sets the mount and dismount to one magazine for the Exabyte 218 and the
    Exabyte 220 changers.
3.  Corrects the Compaq support for the Compaq 4/8 SLR tape drive and the
    Compaq DDS3 changer.

SLS APP618A adds support for the following tape devices:

Note: Not all these devices have been certified yet; see the OnLine SCO Compatible Hardware web page found at http://www.sco.com/chwp. The term "supported" here means that the software will recognize the device, but it does not necessarily mean that the device is officially certified. Only devices that are officially certified are guaranteed to work as expected.

- Quantum Powerstor L200 and L500 changers - Quantum DLTStor changers - ATL L200 and L500 changers - Exabyte 230D changer - HP A4853A changer - HP A4846A changer - Del 130T changer - Compaq 12/24/DAT LIB - Digital TL891 changer - Digital TL810/812 changers - Tandberg SLR5 tape drive - Tandberg NS20 Pro (TR5) - Aiwa TD-20001 tape drive (TR5) - HP T20 (TR5) - Seagate NS8/NS20(TR4/TR5) tape drive - Compaq 2/4 GB DAT tape drive - Tandberg SLR6 tape drive - Techmar NS20

- ADIC Faststor FS-DLT4000 DLT changer - Compaq 4/8GB 4mm DAT - Compaq 12/24GB 4mm DAT - Compaq 20/40GB DLT - Compaq 35/70GB LIB DLT changer - Compaq 35/70GB DLT - HP 418 DLT changer - IBM 7331 8mm DAT changer - IBM IBM-85XL 8mm DAT - Overland LXB DLT changer - Quantum DLT4000 DLT - Seagate Scorpion 4 - Seagate Sidewinder - Tandberg MLR1 - Tandberg MLR3 - Tandberg MLR1 QIC - Tandberg MLR3 QIC

Contents
--------
/usr/lib/ARCserve/.tapelist.dat
/usr/lib/ARCserve/tapesvr
/usr/lib/ARCserve/dm
/usr/lib/ARCserve/dbserver
/usr/lib/ARCserve/aprocess
/usr/lib/ARCserve/as_backup
/usr/lib/arcboot/arcboot
/usr/lib/arcboot/.mkfuncs
Software Notes and Recommendations
----------------------------------

SLS APP618A should only be installed on:

SCO ARCserve/Open 2.2.0k (OpenServer 5.0.2, 5.0.4, 5.0.5)
SLS APP618A supersedes APP607A, the Year 2000 Supplement for SCO ARCserve/Open
2.2.0k on SCO OpenServer and the SCO ARCserve/Open 2.2.0 Maintenance Supplement
Release 1.1.0.  Both of these supplements should be removed prior to
installing APP618A.
Installation Instructions
-------------------------
1. Prepare the files for installation.
Download the APP618A media image file (app618a).  Place the file in the
/tmp directory and rename the file by typing these commands:
mv /tmp/app618a /tmp/VOL.000.000

2. Log onto the local server as root and run the Software Manager with the command:

# scoadmin software

or double-click on the Software Manager icon in the desktop.

3. For SCO OpenServer 5.0.4 or 5.0.5, pull down the "Software" menu and select "Install New".

For SCO OpenServer 5.0.2, pull down the "Software" menu and select
"Patch Management  --> Apply Patch".

4. When prompted for the host from which to install, choose the local machine and then "Continue".

5. When prompted to select the media device:

If you are installing this SLS from media images, select "Media Images",
then "Continue".  When prompted for the "Image Directory", enter
"/tmp" (or the directory where you placed the VOL.000.000 file in step 1)
and then select "OK".
6. For SCO OpenServer 5.0.4 or 5.0.5, when prompted to select software to
   install, ensure that the "APP618A: SCO ARCserve/Open 2.2.0 Maintenance
   Supplement" entry is highlighted.  Choose "Install".

For SCO OpenServer 5.0.2, when prompted to select installation type, choose "Full".

7. Once the installation finishes, quit the Software Manager.  Installation
   of this SLS is now complete.

8. You will need to restart the SCO ARCserve/Open daemons by running the following command as root:

# astart
Removal Instructions
--------------------
Note: Patches must be rolled back in the reverse order in which they were
installed on a per -component basis.  Hence, if this patch is not the most
recent patch applied to the UNIX component of the product, you will have to
roll back all patches applied after this patch prior to rollback of this patch.

To remove SLS APP618A take these steps:

I. Removing SLS APP618A from SCO OpenServer 5.0.4 or 5.0.5

1. Log in as root.
2. Execute the command:
# scoadmin software

or double-click on the Software Manager icon in the desktop.

3. Highlight "APP618A: SCO ARCserve/Open 2.2.0 Maintenance Supplement".

4. Pull down the "Software" menu and select "Remove Software".

5. Once the removal finishes, quit the Software Manager.  Removal of
   this patch is now complete.

6. You will need to restart the SCO ARCserve/Open daemons by running the following command as root:

# astart
II. Removing SLS APP618A from SCO OpenServer 5.0.2
1. Log in as root.
2. Execute the command:
# scoadmin software

or double-click on the Software Manager icon in the desktop.

3. Pull down the "Software" menu and select "Patch Management -->Rollback Patch".

4. You will see the "Begin Rollback Patch" menu, and be asked to select patched software to roll back. Select "SCO ARCserve/Open for SCO OpenServer Release 5" and choose "Continue".

5. You will see the "Patch Selection" window. Make sure that the "APP618A: SCO ARCserve/Open Maintenance Supplement" is selected, and choose "Continue".

6. You will see the "Confirm Selected Patches" window.  Choose "Rollback"
   to confirm removal of the "APP618A: SCO ARCserve/Open Maintenance
   Supplement".

7. You will see the "Rollback Progress" window, as the system performs the rollback of the patch.

8. You will need to restart the SCO ARCserve/Open daemons by running this command as root:

# astart

If you have questions regarding this SLS, or the product on which it is installed, please contact your software supplier.

From the Xinuos technical article database, record 110887. Reproduced with permission. The original is at www.sco.com/ta/110887, which is reachable but blocked from search engines. Xinuos marks this article against a retired product line. That refers to the product’s lifecycle, not to whether the advice still works — plenty of it still applies to running systems.

Next step

Need this fixed rather than explained?

Tell us the release, what the system runs and what it is doing. We will reply by email with what we would do next.

  • You deal with the people who do the work
  • No obligation, and no upgrade required before we will help
  • We tell you plainly if something is not worth doing

Send an enquiry

We reply by email. If a server is down, say so in the first line. You can also write to help@scoexpert.com.