Technical article 110059

What SCO operating systems support setting the CMOS Century Byte?

OpenServer 5.0.0OpenServer 5.0.2OpenServer 5.0.4OpenServer 5.0.5UnixWare 7.0.0UnixWare 7.0.1UnixWare 7.1.0

Written · Last revised

Problem

What SCO operating systems support setting the PC CMOS century byte?

Solution

SCO operating systems only read the 2-digit year value in Byte 9 of the CMOS to determine the 4-digit year. The operating systems use the following algorithms to determine the 4-digit year:

If the Year byte (yy) is in the range 69-99, then the 4-digit year is 19yy.

If the Year byte (yy) is in the range 00-68, then the 4-digit year is 20yy.

Because SCO operating systems do not require the century byte (byte 50 in the CMOS of an AT architecture system and byte 55 on a PS/2 architecture system) to calculate the 4-digit year, and because the original IBM AT specification never specified that the century byte be used, SCO operating systems did not, historically, write the century byte when updating the RTC.

Some incorrectly written BIOSes use the century byte in the CMOS and cannot handle 2-digit year values. Operating systems that use the BIOS to read and write time, like DOS and Windows, fail to get the correct time and date because of this.

To avoid problems, where DOS, Windows or the BIOS fails because the century byte is not updated on systems where they coexist with an SCO operating system, the following SCO operating systems support updating of the century byte:

For SCO OpenServer Release 5:

SCO OpenServer Release 5.0.0 with SLS OSS496A applied SCO OpenServer Release 5.0.2 with SLS OSS496A applied SCO OpenServer Release 5.0.4 with SLS OSS496A applied SCO Internet FastStart Release 1.1 with SLS OSS496A applied SCO OpenServer Release 5.0.5 with Release Supplement 505A

For SCO UnixWare Release 2.1:

SCO UnixWare Release 2.1.2 with SLS PTF3391A applied SCO UnixWare Release 2.1.3 with SLS PTF4003B applied

For UnixWare 7:

UnixWare 7 Release 7.0.0 with PTF7034A applied UnixWare 7 Release 7.0.1 with PTF7034A applied UnixWare 7 Release 7.1.0

From the Xinuos technical article database, record 110059. Reproduced with permission. The original is at www.sco.com/ta/110059, which is reachable but blocked from search engines. Xinuos marks this article against a retired product line. That refers to the product’s lifecycle, not to whether the advice still works — plenty of it still applies to running systems.

Next step

Need this fixed rather than explained?

Tell us the release, what the system runs and what it is doing. We will reply by email with what we would do next.

  • You deal with the people who do the work
  • No obligation, and no upgrade required before we will help
  • We tell you plainly if something is not worth doing

Send an enquiry

We reply by email. If a server is down, say so in the first line. You can also write to help@scoexpert.com.