Technical article 109466

When configuring an IBM 16/4 ISA Token Ring Network Adapter, I am not prompted for the IRQ or I/O address.

OpenServer 5.0.0OpenServer 5.0.2OpenServer 5.0.4

Written · Last revised

Problem

When configuring an IBM 16/4 ISA Token Ring Network Adapter, I am not prompted for the IRQ or I/O address.

Cause

This particular network card has a switch block at the end which allows you to configure whether it is "primary" or "secondary". When you run netconfig(ADM) to configure the card at the software level, you are asked to choose whether the card is primary or secondary, along with the RAM address.

This card only supports two I/O addresses.  When you select primary
or secondary, you are effectively choosing the I/O address, and all
other configurable options are read directly from the card using
this address.

Solution

Double-check the switch block settings to make sure you have all
the DIP switches set correctly.  The manual that comes with the
card has all options diagrammed with a complete explanation of
each setting.
Some older cards require a power off of the card after setting the
switches.  The driver will read the new switch value on reboot.

From the Xinuos technical article database, record 109466. Reproduced with permission. The original is at www.sco.com/ta/109466, which is reachable but blocked from search engines. Xinuos marks this article against a retired product line. That refers to the product’s lifecycle, not to whether the advice still works — plenty of it still applies to running systems.

Next step

Need this fixed rather than explained?

Tell us the release, what the system runs and what it is doing. We will reply by email with what we would do next.

  • You deal with the people who do the work
  • No obligation, and no upgrade required before we will help
  • We tell you plainly if something is not worth doing

Send an enquiry

We reply by email. If a server is down, say so in the first line. You can also write to help@scoexpert.com.