Technical article 112603

When I try to run "net" commands to add users, I get Error 53 messages.

OpenServer 5.0.4OpenServer 5.0.5OpenServer 5.0.6

Written · Last revised

Problem

I want to run the net commands from the Unix prompt, but it complains with Error 53 Permission Denied.

# net logon
Type your user name, or press ENTER if it is ADMINISTRATOR:
Type your password:

By default, when you log on as root you already have ADMINISTRATOR privilege and will be able to run NET commands. However, once you run the "net logoff" command you must use "net logon" to log in again.

When I try to run "net" commands to add users, I get Error 53
Permission Denied messages.  During the logon process I received
this error message:

You were logged on, but have not been validated by a server. Therefore, you may not have permission to use some network resources.

Cause

The password is incorrect for the ADMINISTRATOR.

Alternatively, AFPS may not be able to successfully resolve the name of your server by the PDC in the domain in which you wish to log on to, or on the PDC of the domain in which this server belongs.

This is normally a result of either a DNS naming problem or a Microsoft WINS name resolution problem.

Solution

If the "lmhosts" file is being used by the PDC in either an SCO AFPS or Microsoft NT environment, then check that the lmhosts file contains the name of this server. Also, if WINS is used, check that the LMHOSTS file has been imported into the WINS database.

Alternatively, there may be an issue with the distance between this
server and communicating with the nearest Domain Controller, which
is required for authentication.  This can be caused by heavy
network or server load. Therefore, it is recommended to have no
more than 24 Domain Controllers in an NT Domain.

See also

ta100037, "What is the 'lmhosts' facility and how is it used?"

From the Xinuos technical article database, record 112603. Reproduced with permission. The original is at www.sco.com/ta/112603, which is reachable but blocked from search engines. Xinuos marks this article against a retired product line. That refers to the product’s lifecycle, not to whether the advice still works — plenty of it still applies to running systems.

Next step

Need this fixed rather than explained?

Tell us the release, what the system runs and what it is doing. We will reply by email with what we would do next.

  • You deal with the people who do the work
  • No obligation, and no upgrade required before we will help
  • We tell you plainly if something is not worth doing

Send an enquiry

We reply by email. If a server is down, say so in the first line. You can also write to help@scoexpert.com.