Problem
How can I disable the keep-alive packets that are sent out on the network by the IPX/SPX protocols?
Solution
Within the IPX/SPX protocol suite, keep-alive packets are only sent out by NVT and SPX.
Keep-alives and SPX:To disable the keep-alive packets in SPX, edit the file:
/etc/conf/pack.d/spx/spx_tune.hand set the value of the SPX_WATCHEMU_INTERVAL parameter to 0.
SPX_WATCHEMU_INTERVAL specifies the interval in minutes that
the SPX watchdog runs. The SPX watchdog ensures that the kernel
resources allocated to SPX are kept to a minimum and that all
dead connections are closed.NOTE: The SCO servers on both ends of an SPX connection send keep-alive packets, so these must be disabled on both machines.
Instead of disabling the SPX keep-alives, increase the time between
keep-alive packets in SPX by modifying the SPX_WATCHEMU_INTERVAL
parameter in the same file. The value of this parameter is in
minutes.When the changes have been made, the kernel will need to be relinked and rebooted in order for the changes to take effect.
Keep-alives and NVT:Keep-alive packets cannot be completely disabled in NVT, but the time interval between them can be increased. In order to increase this time, edit the file:
/etc/conf/pack.d/nvt/nvt_tune.hand modify the value of the NVT_KEEP_ALIVE_INTERVAL_TIME
parameter. This value is in clock ticks (there are 100 ticks
per second). NVT_KEEP_ALIVE_INTERVAL_TIME specifies how long
NVT should wait before checking on inactive connections. It
determines when the first watchdog packet is sent to an inactive
connection. Increase the value of this parameter if NVT is used
on a large network with slow routers between the client and the
host. Decreasing this value allows the host to detect downed
clients in a more timely manner.When the changes have been made, relink and reboot the kernel in order for the changes to take effect.
See also
TA101288, "What are the different protocols for NetWare, and which ones does SCO support?"