Technical article 117050

Compaq OpenServer 5 systems hangs on boot with boot letter "G" (hd_config), after installing supplements/EFS/Insight Manager.

OpenServer 5.0.0OpenServer 5.0.2OpenServer 5.0.4OpenServer 5.0.5OpenServer 5.0.6OpenServer 5.0.7

Written · Last revised

Problem

OpenServer 5 is installed on a Compaq system.  After either
installing later supplements (SLSs) or upgrading/adding to the Compaq
EFS/Insight Manager agent packages, the kernel is relinked and system
rebooted. However, it hangs on reboot during the hardware recognition
screen after displaying the boot letter "G" (hd_config).

This has specifically been reported on a Compaq ML350 server with OpenServer 5.0.5 and Compaq EFS 5.46 (and related Compaq Insight Management agents) when the supplements rs505a, oss497c and oss600a were installed.

Solution

Ensure that only the specific components of the EFS and Insight
Managements agents relevant to the hardware are installed and remove
all other components.  The OS supplements should be installed.
In general, this is good advice to only have the EFS drivers and
Insight Management agents installed to support your specific
hardware.  Installing additional agents, which don't have the required
hardware available, can cause strange results (at the very least
filling up log files with error messages indicating that the resource
is not available).

In the specific instance described above, the issue was resolved by removing all the SLSs and the EFS, leaving only those parts strictly needed. For example, the Netflex driver and the agent. The SLSs were then reapplied, the kernel relinked and the system successfully rebooted.

NOTES:    There are other possible causes of the system hanging on boot at
          G hd_config (such as SMP issues).

For OpenServer 5.0.5: One specific issue is resolved in the supplement rs505a.

For OpenServer 5.0.6 / 5.0.7: Check that the IDE CD Drive is NOT on
Cable Select.  Select Master using the built in Dip Switches on the
CD Drive.

From the Xinuos technical article database, record 117050. Reproduced with permission. The original is at www.sco.com/ta/117050, which is reachable but blocked from search engines.

Next step

Need this fixed rather than explained?

Tell us the release, what the system runs and what it is doing. We will reply by email with what we would do next.

  • You deal with the people who do the work
  • No obligation, and no upgrade required before we will help
  • We tell you plainly if something is not worth doing

Send an enquiry

We reply by email. If a server is down, say so in the first line. You can also write to help@scoexpert.com.