Technical article 127094

How can I install OpenServer 5.0.7 on the ASUS F8Vr Laptop?

OpenServer 5.0.7

Written · Last revised

Problem

How can I install OpenServer 5.0.7 on the ASUS F8Vr Laptop?

HARDWARE: The hardware configuration of the ASUS F8Series (F8Vr) this article was tested with is:

CPU: Intel Core 2 Duo P8400 (Montevina) on an Intel PM45 motherboard RAM: 3GB DDR2 800 Hardisk: Samsung HM160HI SATA 160GB Graphic card: ATI Mobility Radeon HD 3470 256 MB VRAM Network Card: Realtek PCI-E Gbit Network card RTL BIOS: AMI Version 205

Solution

Before you install:
------------------
	  NOTE on the wd driver:
	  ---------------------
	  There is a special boot parameter for the wd driver required to get
          this type of machine installed.
          (wd.atapishift - see further down below for the details)
	  NOTE on the special BTLD Boot CD image that is required:
	  -------------------------------------------------------
	  The machine needs to be installed using a special BTLD Boot CD with
          an updated wd driver.

You would need to follow TA126828 in order to create a BTLD BOOT CD with an updated wd driver. (version 3 or later)

The wd driver that is included in the OpenServer 5.0.7 installation CD image does not detect the disk controller.

We have already done this for you. The image can be downloaded from:

ftp://ftpput.sco.com/tmp/osr507boot-CD-wd-v3.iso

Download and burn a CD for installing this machine from.

	  Note on SMP:
	  ------------
	  If you install SMP (to utilize 2 core's) you will see a message like:

Warning: apic - no BIOS information found for IRQ 6

If you reboot after you have installed SMP without installing MP5 immediately after SMP, the system will PANIC.

In that case, boot with unix.old into Maintenance mode and install
MP5.  (or any later version of the maintenance pack)
	  A note on BIOS settings:
	  -----------------------
          1) OpenServer 5.0.7 does not support ahci mode with the onboard
             S-ATA controller available in this machine.

You will need to enter the BIOS (Press F2 during system start), change to the "Advanced Menu" Tab -> "IDE Configuration" and change the SATA Operation Mode from "Enhanced" to "Compatible".

2) You will need to disable the USB subsystem during installation since the USB implementation that ships with OpenServer 5.0.7 is incompatible and will result in a PANIC during installation. (see Technical Article 127056).

The ASUS F8Series BIOS has a "Security -> I/O Subsystem Security Menu" that allows to "LOCK" the USB components. Setting "LOCK" will disable all USB devices. (The BIOS Default is UNLOCKED)

We will re-enable USB after we have the system installed and the latest Maintenance Pack applied.

-------------------------------------------------------------------------------
Installation:
------------
You need both the BTLD Boot CD with the new "wd" BTLD and
the July 2005 cut (or later) of SCO OpenServer 5.0.7 install CD.

Boot the server with the BTLD Boot CD. At the boot prompt, type "dir" to check if "wd" is there.

boot
 : dir

Now add the following install boot string:

boot
: defbootstr link=fd(64)wd wd.atapishift<RETURN>
Please Note:
"link=fd(64)wd" is equvilant to "link=wd btld=fd(64)"
At the message below, just hit the <RETURN>

Please insert the fd(64)wd volume and press <Return> or 'q' to quit: <RETURN>

The boot sequence will then load the "wd" BTLD from the BTLD Boot CD and you will notice that the "wd" was successfully loaded and linked to the install Kernel.

A message informs you about that the wd driver apparantly needs to
be replaced.  (Press 'r' to replace the existing wd driver)

While the hardware information is displayed, you will notice a message similar to:

NOTICE: wd ATAPI Device at 2/0 will appear as primary master for OS Install

That is the result of the wd.atapishift command and is important for the installation.

Without that parameter you will not be able to access the CD-ROM drive during and cannot continue the installation.

Continue the installation and confirm with OK on the screen message:

Please insert (wd) package BTLD disk into the floppy drive so that it can be extracted onto the hard disk for incorporation into the link-kit.

at the "Media device to be used" screen, remove the BTLD Boot CD and insert the SCO OpenServer 5.0.7 Install CD.

Regardless of any further suggestions, there will be no need to insert the new BTLD Boot CD again.

Continue the installation with keyboard, license and disk configuration....etc

Network:
--------
When you are prompted to configure the Network Card choose:

"Defer" as the Realtek network card is not supported by the OpenServer 5.0.7 Installation CD.

We will configure the Realtek card once installation is complete.

Graphical Login:
---------------
When you are prompted for the video configuration, choose:

VESA SVGA (default), press the space key and set Graphical login to : scologin off.

After the latest Maintenance Pack later on has been installed, we will enable scologin.

Mouse:
-----
Choose Low resolution keyboard Mouse. If you use an
external USB mouse, you need to use the "mkdev mouse"
command, after Openserver 5.0.7 and the latest Maintenance
Pack has been installed and USB has been UNLOCKED then in the BIOS.

When the installation gets to the point where it wants to load "wd" BTLD into link-kit, you will then get this error message:

The BTLD package will now be extracted
mount: Bad address
Please select the floppy device you are using
(1) /dev/fd0
(2) /dev/fd1

choose option (2) and you will be asked to insert the wd BTLD floppy disk again:

Please insert the floppy for BTLD package: wd and press <Return>:

Press RETURN and you will then get this message:

mount: Bad address, Could not mount the BTLD floppy
You may:

(a) try again (b) abort BTLD load, but continue installation (c) abort the installation

Respond with one of (a,b,c):
choose option "b".

We will later load the wd BTLD into the link-kit at the post installation.

The installation will continue and OpenServer 5.0.7 will get installed on to the Hard Drive.

Please Note:

The finished installed OpenServer 5.0.7 kernel will not have the "wd" BTLD linked to it. So if you now try to reboot, OSR507 will fail to boot from the HD. -------------------------------------------------------------------------------

POST Installation:
-----------------
When the installation has finished, remove the SCO OpenServer 5.0.7
Install CD and insert the BTLD Boot CD again and reboot the server.

At the Boot prompt, enter the following boot string:

boot
: defbootstr link=fd(64)wd wd.atapishift root=hd(42)
             Srom=wd(0,0,0,0)

Boot using the install unix kernel on the BTLD Boot CD (OSR507 install kernel), bind the wwd driver to the install kernel, CD-ROM drive attached to PRIM IDE controller as master and use the root filesystem on the Hard Drive hd(42). (OSr507 is already installed on the hard drive).

Please Note: The Srom and the wd.atapishift in the boot string is VERY important to add.

Failing to add it, will result in failure accessing the CD-ROM device /dev/cd0.

Continue as before and hit RETURN at the message:

Please insert the fd(64)wd volume and press <Return> or 'q' to quit: <RETURN>

to load the "wd" BTLD.
	  Press R to replace the driver.

At the INIT: SINGLE USER MODE, enter the root password to enter into system maintenance mode.

Mount the BTLD Boot CD and install the "wd" BTLD:

# mount /dev/cd0 /mnt
# mkdir /mnt2
# marry -a /mnt/osr507boot-CD.img
# mount -r /dev/marry/mnt/osr507boot-CD.img /mnt2
# btldinstall /mnt2

You will be given the wd BTLD on the list.

Press RETURN to choose the default "wd".

The BTLD wd gets loaded and then OpenServer 5.0.7 will tell you that the "wd" is already installed and you are requested to proceed with "y" to install and over write the old "wd" driver or "n" for NO and exit.

Proceed with "y" to update the "wd" driver and then "y" to relink the kernel.

If you are not asked to build the kernel, run:

# /etc/conf/cf.d/link_unix -y

Un-marry and unmount the BTLD Boot CD and reboot:

# umount /mnt2
# marry -d /dev/marry/mnt/osr507boot-CD.img
# umount /mnt
# init 6

Remove the CD from the CD-ROM drive.

At the boot prompt you need to add the following bootstring, otherwise you cannot use the CD-ROM drive.

	  	boot:defbootstr wd.atapishift

It's NOT recommended to add this boot parameter into the file /etc/default/boot at the end of the DEFBOOTSTR definition.

If you do, it would probably look like this:

DEFBOOTSTR=hd(40)unix swap=hd(40) dump=hd(41) root=hd(42) wd.atapishift
	  Please note, that after installing MP5 and re-installing the latest
          wd driver after it, you might not be able to access your cd-rom
          drive.

You need to use 'mkdev cdrom' to configure the cd-rom drive. (see further down below)

SCO OpenServer 5.0.7 is now installed on a machine where a BTLD was loaded via CD-ROM during installation on a machine with no Legacy Floppy drive or USB floppy drive.

	  Network configuration:
          ----------------------
          Download and the driver for the Realtek network card (and burn it
          onto a CD) from:
http://www.realtek.com.tw/
Look for the RTL8111B/RTL8168B/RTL8111/RTL8168/RTL8111C
Software Download.

At the time of this writing this has been version 1.0.6 from 01.08.2008

If you copy it from a CD and have problem with accessing the CD-rom drive, use the wd.atapishift boot parameter during reboot or in /etc/default/boot

Use custom to install the files.(e.g. from a USB memory stick)

(you need to unpack them first and might need to rename a file like GBE.vol into VOL.000.000 and then use custom to install from media images)

Run netconfig and add the new adapter. You need to scroll down in the list of adapters and choose:

"Realtek RTL8169/8168/8110 Family Gigabit PCI Adapter"

Configure TCP/IP and then relink and reboot.

	  Prepare for later installation of the updated wd driver:
          -------------------------------------------------------
	  Download the latest wd driver for OpenServer 5.0.7 from the SCO
          Support Download Page and save it on your disk. (e.g. in a
          /local/software directory)

The driver is provided as a btld image.

SMP software installation:
-------------------------
This machine is using a Core 2 Duo processor. In order to
utilize both Cores you need to install the SMP software
from the OpenServer 5.0.7 installation CD. (before
installing a Maintenance Pack)

You do not need to license the second core, hence while being asked for a license during SMP installation, simply choose DEFER.

          IMPORTANT:
          ---------
          BEFORE you reboot after SMP installation, install MP5, including the
	  SMP patch. Otherwise your system will PANIC during next reboot. (in
          that case boot from unix.old into Single User mode and install MP5)
Maintenance Pack installation:
------------------------------
Now install the latest Maintenance Pack. (MP5 at the time
of writing).
This is a prerequiste before you can use SMP and before you can
enable USB in the BIOS again.

Please Note: MP5 contains an older version of the wd driver and replaces your latest wd driver.

You need to update the wd driver again to the latest version available in the SCO Support Download area.

(see further down below WD driver update)

Please Note: at this stage with an older version of the wd driver and even if wd.atapishift still set, you might not be able to access the cd-rom drive. (cannot stat /devcd0 if you try to mount it).

	  You need to re-install the latest wd driver and use mkdev cdrom in
          order to fix this.   (see below)
          WD driver update:
	  ----------------
	  You have downloaded the btld image of the latest wd driver package
          to your disk already.

(see above) - e.g. into the /software directory on your disk.

	  Use marry:
                   # mkdir /mnt3
		   # marry -a /software/wd_v3.0_btld.img
                   # mount -r /dev/marry/software/wd_v3.0_btld.img /mnt3
                   # btldinstall /mnt3

Install the wd driver and relink the kernel and reboot.

	  CD-ROM drive
	  ------------
	  If you still have set wd.atapishift in /etc/default/boot, then your
          CD-ROM drive will work.
	     (you can mount /dev/cd0 /mnt but it is not recommended to set
              atapishift by default.)

Otherwise you need to use mkdev cdrom to first remove the configured ATAPI CD-ROM and to add a new ATAPI CD-ROM drive. (e.g. controller 2)

	  # hwconfig |grep cd-rom output should look like:
	  name=cd-rom vec=- dma=- txpe=IDE ctrl=2 cfg=mst unit=0 dvr=Srom->wd
	  and
# mkdev .scsi output (Option 3) should look like:
	  Type	Host Adap	Device	Ad Number	ID	LUN	Bus
	  -----------------------------------------------------------------
	  USB	usb_msto	disk	0		0	0	0
	  ATAPI	wd		cd-rom	2		0	0	0

Enable USB: ---------- Enter the BIOS and enable USB in the I/O Security menu. You can then use a USB memory stick (mkdev hd) or USB mouse. (mkdev mouse)

	  USB Mouse:
	  ---------
          Use mkdev mouse if you want to configure a USB mouse.
Enable scologin, if required:
----------------------------
Use "scologin enable" in order to enable the graphical login.

Use scoadmin video to configure a higher (VESA based) resolution.

During the test, 1024x768x65K colors has been used.

From the Xinuos technical article database, record 127094. Reproduced with permission. The original is at www.sco.com/ta/127094, which is reachable but blocked from search engines.

Next step

Need this fixed rather than explained?

Tell us the release, what the system runs and what it is doing. We will reply by email with what we would do next.

  • You deal with the people who do the work
  • No obligation, and no upgrade required before we will help
  • We tell you plainly if something is not worth doing

Send an enquiry

We reply by email. If a server is down, say so in the first line. You can also write to help@scoexpert.com.