Technical article 125303

How do I add a tape on the second channel of an IBM ServeRaid 5I or 6M controller?

OpenServer 5.0.5OpenServer 5.0.6OpenServer 5.0.7

Written · Last revised

Problem

How do I add a tape drive on the second channel of an IBM ServeRaid 5i controller that is using the ips driver?

Solution

The ips RAID controller is using the bus to identify the different channels.

First Channel is equivalent to bus=1 Second Channel is equivalent to bus=2

To configure a tape drive on the second channel of the ips Raid controller run the mkdev tape command and use the following options:

ha=0 bus=2 id=<SCSI id> lun=0

From the Xinuos technical article database, record 125303. Reproduced with permission. The original is at www.sco.com/ta/125303, which is reachable but blocked from search engines.

Next step

Need this fixed rather than explained?

Tell us the release, what the system runs and what it is doing. We will reply by email with what we would do next.

  • You deal with the people who do the work
  • No obligation, and no upgrade required before we will help
  • We tell you plainly if something is not worth doing

Send an enquiry

We reply by email. If a server is down, say so in the first line. You can also write to help@scoexpert.com.