Problem
After installing the System Security Enhancement SSE072B on my OpenServer 5 system, I receive the following error upon logging in:
dynamic linker: tput: symbol not found: strlcpyOn terminals where I am usually prompted to specify the terminal
type, I am no longer prompted and the correct terminal type is not
set.This problem does not happen on OpenServer 5.0.6 with RS506A installed.
Cause
SSE072B contains a replacement /usr/bin/tput binary to fix a
buffer overflow. The replacement version utilizes the "strlcpy"
function, which is only available in the standard shared C library
starting in 5.0.6 with RS506A installed. When this function,
which does not exist on these pre-RS506A systems, is called,
tput exits and therefore cannot complete its task successfully. Solution
This problem is fixed by SSE072C.You can download SSE072C from:ftp://stage.sco.com/pub/security/sse/sse072cYou do not need to remove previous versions of SSE072 before installing SSE072C.
NOTE: Although a buffer overflow has been found in the tput binary, this
utility is not a setuid binary, and hence no security threat is
posed by this buffer overflow. Nevertheless, the buffer overflow
in tput has been addressed in SSE072C. See also
ta113723, "What is SSE072C, the buffer overflow security patch for Openserver 5?"