Problem
I get a message similar to the following:
ERROR: floppy read error on dev 2/64 blk=0 cmd0x03 status=0x01
The hardware and media are both known to be good.
Cause
There can be timing issues, especially with fast CPUs, where the floppy device fails to read or write without errors.
Solution
The floppy driver is located in /etc/conf/pack.d/fd/. There are three files: Driver.o, device.dat and space.c. The device.dat contains information which is placed in the /etc/conf/cf.d/sysRegistry file.
One test is to move the sysRegistry file out of the way and attempt to perform the failing floppy operation. If this resolves the issue, then there is a parameter within the device.dat that is incorrect.
Note: Modification of the device.dat or sysRegistry files is
beyond the scope of this article. Contact your Technical Support
provider for more in-depth assistance.If there is still a problem, return the sysRegistry file and edit the /etc/conf/pack.d/fd/space.c file and locate the last two lines. Modify them in the following way:
Change:int fd_enable_FIFO = 0;
int fd_FIFOthresh = 0;to:int fd_enable_FIFO = 1;
int fd_FIFOthresh = 8;Note: The fd_FIFOthresh value pertains to a 16-byte buffer. If the value of 8 doesn't work, retry with a value of 2. There have also been some instances where a threshold value of 'f' worked.
Relink and reboot the system. See also
TA105025, "How can I use the Software Manager/custom(ADM) with a non-standard device?"