Problem
After installing Support Level Supplement (SLS) OSS491A, the Kernel and SMP Supplement for OpenServer 5.0.5, attempting the following procedure results in netconfig hanging (requiring it to be killed from a separate session):
Start netconfig from the SCOadmin launcher, by selecting the Network Configuration Manager in the networks folder.
Take the menu option "Add new LAN adapter".
Select the model of LAN adapter required.
Click OK on the Network driver configuration window.
Click OK on the pop-up titled "Please verify adapter is set to config. just entered". netconfig hangs at this point.
Netconfig also hangs if attempting to use other menu options.
Other SCOadmin functions, such as Software Manager -> Software -> -> Install New, may fail.
Solution
One solution is to remove SLS OSS491A (using the procedure in the SLS cover letter - see ta109741), before using netconfig, then reinstall SLS OSS491A.
A second solution is to apply Release Supplement RS505A. This
supplement reinstalls the older spt driver in order to prevent
the netconfig hangs. You do not need to remove OSS491A before
applying RS505A.A drawback of the second solution is that fixes for the following two issues, addressed by SLS OSS491A, will no longer be installed:
numlock/capslock anomalies in scotermhpnptyd runs in an endless loopA third solution is to use the following procedure to replace the OpenServer spt Driver.o introduced by SLS OSS491A with the backup Driver.o created when this SLS was installed:
# cd /etc/conf/pack.d/spt
# mv Driver.o /spt_Driver.o.orig
# cd /opt/K/SCO/link/oss491a.link111.1.0a
# cd patch_backup/etc/conf/pack.d/spt
# cp Driver.o /etc/conf/pack.d/spt
# cd /etc/conf/cf.d
# ./link_unix -yReboot the systemThis third solution, of course, has the same drawbacks as noted above for the second solution.
See also
man page kill(C)ta109741, "What problems are addressed by OSS491A, the Kernel and SMP Supplement for OpenServer 5.0.5?"
ta109909, "What is Release Supplement 505A for SCO OpenServer Release 5.0.5?"