Problem
I need to update my system to interpret the new US Energy Policy Act of 2005 rules for Daylight Saving Time (DST).
Why should I have to install a patch to my system when simply explicitly setting the TZ environment variable in /etc/TIMEZONE will address this issue?
Solution
The application of the relevant SCO OpenServer 5 DST patch to your system has the following advantages:
1) There is no requirement to edit either- the system wide TZ environment variable - the TZ environment variable of individual users - or the TZ environment variable set by individual applications or scripts
If an SCO User chooses not to apply the patch then they will need to locate every instance of the TZ variable used on the system and update it. This is a far from straightforward task on systems where users, applications and scripts have set their own TZ environment variable values.
2) There is no requirement on the part of the installer to know what the syntax of the rule changes are for the various US and Canadian Timezones.
If an SCO User chooses not the apply the patch then they will need to know how to correctly set the TZ.
The syntax is complex and mistakes are easily made.
3) Application of the patch will ensure that calculation of times and dates prior to 2007 take into account the old DST rules.
If an SCO User chooses not to apply the patch then if they are running applications that calculate dates in the past then those dates will have the new (and wrong) DST rule applied to them instead of the old DST rules.
The application of the DST patch requires the following tasks, which are not required with the alternative updating of TZ:
1) You must download and install software onto all systems that are affected.
2) If applications are using a statically linked libc then
the installation of the patch will not automatically fix these
applications. You must recompile the applications on a development
system on which the DST patch has been installed.NOTES: manual change may not address all instances of Time zone variables to accommodate for the new rules. In the event that it fails to make the necessary adjustments, your system may encounter problems ranging from minor inaccuracies to highly significant problems depending upon the details of your environment. Additionally, any errors made in implementing the change can result in severe problems.
SCO Custom patch deliverables include assistance by allowing a 30 day test period during which SCO Professional Services will assist with resolving possible implications caused as a direct result of the patch and its intended functionality.