Technical article 126813

How can I get a MultiTech MT5634ZPX-PCI V.92 Internal PCI Modem to work with SCO OpenServer 5.0.7?

OpenServer 5.0.7

Written · Last revised

Problem

How can I get a MultiTech MT5634ZPX-PCI V.92 Internal PCI Modem to work with SCO OpenServer 5.0.7?

HARDWARE: MultiTech MT5634ZPX-PCI V.92 Internal PCI Modem

Solution

This is what you need to do in order to get the MultiTech
MT5634ZPX-PCI V.92 Internal PCI Modem to work with SCO
OpenServer  5.0.7:

In our example, we will communicate with the MultiTech MT5634ZPX-PCI Modem via COM3 (We want to keep COM1 & COM2 free for other use).

1- Make sure that you have the following installed first:

OpenServer 5.0.7 Maintenance Pack 5
http://www.sco.com/support/update/download/release.php?rid=186

The MultiTech MT5634ZPX-PCI Modem is plugged in a free PCI slot. Recommended a 32bit PCI slot. If non available, then a 64bit PCI slot.

2- With the modem installed, boot up the server and find out the port addresses and IRQ for the MultiTech MT5634ZPX PCI Modem:

# hw -v -r pci
(In our installation, we got this output: )
Index: 19
DeviceNum:      5
Function:       0
Bus:            20
VendorId:       0x11c1      At&t Microelectronics
DeviceId:       0x0480
RevId:          0x00
Command:        0x0347      Memory Enabled, I/O Enabled
Status:         0x0290
ClassCode:      0x078000    Other communications device
CacheLineSize:  0           No limiting
LatencyTimer:   0x00
HeaderType:     0x00        Single-function, Standard encoding
SelfTest:       0x00        Not BIST capable
BaseAddr[0]:    0xfd404000  Memory 0xfd404000, 32 bit space
BaseAddr[1]:    0x00005801  I/O 0x5800
BaseAddr[2]:    0x00005401  I/O 0x5400
BaseAddr[3]:    0x00005001  I/O 0x5000
BaseAddr[4]:    0x00000000
BaseAddr[5]:    0x00000000
CardbusCISPtr:  0x00000040
SubsysVendorID: 0x11c1      At&t Microelectronics
SubsystemID:    0x5656
ROMbaseAddress: 0x00000000  Expan ROM   0x00000000, Disabled
InterruptLine:  0x0a        IRQ-10
InterruptPin:   0x01        INTA
Min_Gnt:        0xfc
Max_Lat:        0x0e
New Capabilities
    CapPtr:     0xf8
We see that the IRQ=10 and first I/O base address = 0x5800
(BaseAddr[1]:    0x00005801)
Note these down.

3- Add a new COM3 serial port under OSR507 by running as root:

# mkdev serial
Add -->
Description = IBM-COM3
IRQ = 10
I/O addr = 5800
--> OK --> Close

You will be requested to Relink the kernel. Confirm with "Yes" to relink the kernel.

Then reboot.

4- After reboot, verify that the COM3 is staticly linked in the kernel:

            # hwconfig -hl | grep serial
serial  0x3f8-0x3ff  4  - unit=0 type=Standard nports=1 base=0 16550A/16
serial  0x2f8-0x2ff  3  - unit=1 type=Standard nports=1 base=8 16550A/16
serial 0x5800-0x5807 10 - unit=2 type=Standard nports=1 base=4 16550A/16
To confirm we can access COM3:
# stty -a </dev/tty3a

speed 9600 baud; ispeed 0 baud; ospeed 9600 baud; line = 0(tty); intr = DEL; quit = ^\; erase = ^H; kill = ^U; eof = ^D; eol = ^@; swtch = <undef>; susp = <undef>; start = ^Q; stop = ^S; -parenb -parodd cs8 -cstopb hupcl cread clocal -loblk -ortsfl -ctsflow -rtsflow -ignbrk -brkint -ignpar -parmrk -inpck -istrip -inlcr -igncr -icrnl -iuclc -ixon -ixany -ixoff -isig -icanon min = 4 time = 0 -xcase -echo -echoe -echok -echonl -noflsh -iexten -tostop -xclude -opost -olcuc -onlcr -ocrnl -onocr -onlret -ofill -ofdel -isscancode -autoe -ed_emacs -ed_vi -ed_history

This output confirms that the OSR507 can connected to COM3.

5- Configure a Modem in the scoadmin modem manager.

Note: before you start with the Modem configuration, check the /usr/lib/uucp/default/MultiTech_MT5634ZPX-PCI file and see if you need to modify the Modem intialization string to your needs for dialout or dialin.

Please refer to the MultiTech MT5634ZPX-PCI manual for details on "AT" initialization strings.

# scoadmin modem

Do a manual configuration and choose the following from the lists:

Modem Vendor: MultiTech Systems
Modem Model:  MultiTech MT5634ZPX-PCI
Modem Port:   tty3A
Line Speed:   57600
Answer mode:  Yes or No
Save and exit.

then test the connect to modem from OSR6:

Note: If you configured the Modem for Answer Mode, you need to stop the getty process on the /dev/tty3A in order to carry the test below. Getty will lock /dev/tty3A.

# cu -l tty3A dir
you should get a "CONNECTED".

You can now issue the "AT" modem commands. Please refer to the MultiTech MT5634ZPX-PCI manual for details on "AT" commands.

With this test, it confirms that OSr507 can connect to the modem and ready for dialout and diailin.

See also

Adding modems under SCO openServer 5.0.7:
http://osr507doc.xinuos.com/en/HANDBOOK/modem_adding.html

From the Xinuos technical article database, record 126813. Reproduced with permission. The original is at www.sco.com/ta/126813, which is reachable but blocked from search engines.

Next step

Need this fixed rather than explained?

Tell us the release, what the system runs and what it is doing. We will reply by email with what we would do next.

  • You deal with the people who do the work
  • No obligation, and no upgrade required before we will help
  • We tell you plainly if something is not worth doing

Send an enquiry

We reply by email. If a server is down, say so in the first line. You can also write to help@scoexpert.com.