Problem
How to install SCO OpenServer 5.0.7 on the new HP Proliant ML350 G6?
HARDWARE: HP Proliant ML350 G6- 2x Quad-Core Intel Xeon Processor E5504 (2.00 GHz, 4MB cache, QPI 4.8GT/s). All logical CPU cores where active. - HP Smart Array P400 3GB SAS raid controller (additional) (PCIe) - 6 GB Memory - SATA DVD-ROM Drive attached to Port 2 on the embedded Intel 82801GR with Legacy IDE emulation (hard coded) - 2x Embedded NC326i PCI Express Dual Port Gigabit Server Adapter (Broadcom NetXtreme BCM5715 Gigabit Ethernet)
IMPORTANT Note:The HP ML 350 G6 was certified as compatible by SCO.
Any questions about this installation, please contact SCO support.
Please Note that currently HP does not support SCO OS on any of their new ProLiant G6 series.
IMPORTANT Note:Currently, there is no SCO OpenServer 5.0.7 driver support for the embedded HP Smart Array P410i SAS disk controller.
This compatible certification was done with a HP Smart Array P400 controller. However, HP, from the hardware configuration side, does not officially support the P400 controller on ML350-G6. The officially supported HP Smart Array 3GB SAS raid controller for this model is the P800 which uses the same "hpsas" BTLD driver as the P400.
You could also use any OSR5.0.7 supported 3GB SAS PCI-E controller from HP (HP Smart Array P600), Adaptec or LSI as a boot controller.
Solution
Before Installation
-------------------
You need the following additional HP components:- HP Smart Array P400 3GB SAS Controller (HP Part# 405132-B21)
Please Note:You can also use HP Smart Array P600 SAS controller (HP Part# 337972-B21). But P400 is ideal low cost Raid controller for running internal hard drives.
- 2x HP SAS 4i to Mini SAS 4i 31 inch/.79 meter cable (HP Part # 411100-B21).
This is used to connect SA-P400 Controller to the HP ProLiant ML 350 G6 drive backplane.
Standard Industry Label is - Internal Mini SFF-8087 to SFF-8484 SAS Cable.
For Wiring details please see:ftp://ftpput.sco.com/tmp/support/G6/G6_SmartArray_Wiring.zipIf you where using a Adaptec or LSI SAS raid controller for the boot Disk, then you make sure you get the correct internal SAS cables for them.
Pre Installation
----------------
- Plug the HP P400 card onto any free PCI-E Slot- Use the internal SFF-8087/8484 HP SAS cable and rewire the disk drive backplane to the P400 controller.
- Upgrade the ML350 G6 BIOS to the latest (BIOS release D22 07/24/2009)
- Upgrade the HP Smart array P400 firmware to latest release (current 6.86B - 16 Jul 2009)
- Make the HP P400 the first boot controller in the server BIOS.
- Important: DO NOT DISABLE THE HP P410i SAS Controller in the BIOS.
Even though it is not used, disabling it will prevent a server warm
reboot from functioning.It will result in the server being powered down.
It is recommended to leave the onboard P410i enabled within the server's BIOS.
Software Required
------------------
- SCO OpenServer 5.0.7 Install CD July 2005 recut
- SCO OpenServer 5.0.7 "wd" BTLD version 3.0
- SCO OpenServer 5.0.7 Maintenance Pack 5 (MP5)
- SCO OpenServer 5.0.7 Symmetrical MultiProcessing supplement oss674a
- SCO OpenServer 5.0.7 USB Floppy Driver supplement OSS673aAll above are available at:http://www.sco.com/support/update/download/osr507list.html- HP "hpsas" HBA driver from EFS 5.790a (available from http://www.hp.com/support or contact SCO Support)
Direct ftp URL link is:ftp://ftp.hp.com/pub/softlib2/software1/pubsw-linux/p308000909/v43929/EFS-5.790a-osr5.tar.Z- Broadcom NetXtreme BCM5700 series Gigabit Ethernet SCO Osr507 Drivers ver. 10.0.3 available at:
ftp://ftpput.sco.com/tmp/support/drivers/network/broadcom/osr5/bcme/sco-10.0.3.zipWarning:Do not use the latest "bcme" driver version 10.4.3 whether it is from HP EFS 5.790a or SCO, Broadcom download site.
This Driver version causes OSr507 + SMP to panic on heavy network load on the ML350 G6 with a lock timeout panic in bcmewsrv.
Installation
------------
Please Note:The ML 350 G6 does not come with a Legacy 1.44 MB floppy drive, therefore you need a USB Floppy drive to load the additional BTLDs.
You need to have both SCO "wd" ver. 3.0 BTLD and HP EFS "hpsas" ver 5.790a BTLD on a separate floppy diskette.
- Connect a USB Floppy drive to the ML 350 G6 - Power on the ML350 G6 server with OSR507 Install CD and at the Boot prompt enter the following boot string:
Boot
:defbootstr link="hpsas wd"Both "hpsas" and "wd" BTLD will be loaded via USB Floppy Drive.
- Defer networking (will be done in POST INSTALLATION)
- At some point the ISL will then try to access the floppy drive in order to extract the content of the "hpsas and wd" BTLD to the hard drive and will fail an error:
The BTLD package will now be extracted
mount: Bad address
Please select the floppy device you are using(1) /dev/fd0
(2) /dev/fd1To fix, have the "hpsas" BTLD first in the USB Floppy Drive and choose (2) for /dev/fd1.
Do the same for extracting the "wd" BTLD.
Installation will continue to the end.Post Installation
-----------------
Very Important:In the case you have 2x Quad core CPU and before you install the OSr507 SMP software, you need to carry out the following changes in the BIOS.
Power On the ML 350-G6 and enter the BIOS (F9) and change the following setting:
System Options --> Processor Options --> Processor Core Disable
And change from "All Core Enabled" to "Half Core Enabled"
This will disable 2 cores on each physical Quad CPU giving a total of 4 core CPU (4 logical CPU).
Please Note that OpenServer 5.0.7 scales up to a maximum of 4 Logical CPU.
If you fail to do that, OSR507 boot process will hang (loop) after installing SMP software with this warning message just after the USB stack gets initialized
"WARNING: wd(1) now using polled interface"On this hardware, the SCO OSr507 "wd" driver has issues with SMP installed when all logical CPU where active.
If you have just single Quad Core CPU, then you do not need to carry out the BIOS changes above.
- Install OpenServer 5.0.7 SMP software and license the 2nd physical CPU in "scoadmin license" Manager.
If you have single Quad core, then no need to have an additional CPU license when installing the SMP software.
- Install OpenServer 5.0.7 MP5Please Note:Make sure you deselect the updated "wd" driver that is part of MP5, as this is older release then the current installed 3.0.
When you expand the MP5 list in custom manager, the updated "wd" driver in MP5 will be listed as rs507d - SCO Wd Driver Update (id rs507d.Wd522.1.2a)
If you accidentally installed MP5 wd update driver, then you need to reinstall "wd" ver 3.0 again.
- Install SCO OSr507 Symmetrical Multiprocessing supplement oss674a (IMPORTANT)
Please Note:If you fail to install this supplement, then SCO OSr507 SMP kernel will interpretate each CPU Core as a physical CPU.
This means, you would need an additional 3 CPU OSR507 license for OSR507 to work on all 4 Logical CPUs.
This supplement fixes this issue.- Install SCO OSr057 USB Floppy Driver supplement OSS673a (MP5 introduced a bug to the USB SCSI floppy driver "Sflp" ).
- Install Broadcom NetXtreme BCM5700 series Gigabit Ethernet Drivers ver.10.0.3. Then configure the networking.
Please note, that you have to disable the ASF on the embedded HP NC326i NIC.
Refer to TA126083 for more details TA 126083 See also
TA127507 - How to install SCO OpenServer 6.0.0 on the new HP Proliant ML350 G6?
TA127508 - How to install SCO UnixWare 7.1.4 on the new HP Proliant ML350 G6?