Technical article 127507

How to install SCO OpenServer 6.0.0 on the new HP Proliant ML350 G6?

OpenServer 6.0.0

Written · Last revised

Problem

How to install SCO OpenServer 6.0.0 on the new HP Proliant ML350 G6?

HARDWARE:
          HP Proliant ML350 G6

- 2x Quad-Core Intel Xeon Processor E5504 (2.00 GHz, 4MB cache, QPI 4.8GT/s).

All logical CPU cores where active.

- HP Smart Array P400 3GB SAS raid controller (additional) (PCIe)

- 6 GB Memory

- SATA DVD-ROM Drive attached to Port 2 on the embedded Intel 82801GR with Legacy IDE emulation (hard coded)

- 2x Embedded NC326i PCI Express Dual Port Gigabit Server Adapter (Broadcom NetXtreme BCM5715 Gigabit Ethernet)

IMPORTANT Note:

The HP ML 350 G6 was certified as compatible by SCO.

Any questions about this installation, please contact SCO support.

Please Note that currently HP does not support SCO OS on any of their new ProLiant G6 series.

IMPORTANT Note:

Currently, there is no SCO OpenServer 6.0.0 driver support for the embedded HP Smart Array P410i SAS disk controller.

This compatible certification was done with a HP Smart Array P400 controller. However, HP, from the hardware configuration side, does not officially support the P400 controller on ML350-G6. The officially supported HP Smart Array 3GB SAS raid controller for this model is the P800 which uses the same "hpsas" HBA driver as the P400.

You could also use any OSR6.0.0 supported 3GB SAS PCI-E controller from HP (HP Smart Array P600), Adaptec or LSI as a boot controller.

Solution

Before Installation
-------------------
You need the following additional HP components

- HP Smart Array P400 3GB SAS Controller (HP Part # 405132-B21)

Please Note:

You can also use HP Smart Array P600 SAS controller (HP Part# 337972-B21). But P400 is ideal for running internal hard drives.

- 2x HP SAS 4i to Mini SAS 4i 31 inch/.79 meter cable (HP Part # 411100-B21)

This is used to connect SA-P400 Controller to the HP ProLiant ML 350 G6 drive backplane.

Standard Industry Label is - Internal Mini SFF-8087 to SFF-8484 SAS Cable.

For Wiring details please see:
ftp://ftpput.sco.com/tmp/support/G6/G6_SmartArray_Wiring.zip

If you where using a Adaptec or LSI SAS raid controller for the boot Disk, then you make sure you get the correct internal SAS cables for them.

Pre Installation
----------------
- Plug the HP P400 card onto any free PCI-E Slot

- Use the internal SFF-8087/8484 HP SAS cable and rewire the disk drive backplane to the P400 controller.

- Upgrade the ML350 G6 BIOS to the latest (BIOS release D22 07/24/2009)

- Upgrade the HP Smart array P400 firmware to latest release (current 6.86B - 16 Jul 2009)

- Make the HP P400 the first boot controller in the server BIOS.

- Important: DO NOT DISABLE THE HP P410i SAS Controller in the BIOS.

Even though it is not used, disabling it will prevent a server warm reboot from functioning.

It will result in the server being powered down.

It is recommended to leave the onboard P410i enabled within the server's BIOS.

Software Required
-----------------

- SCO OpenServer 6.0.0 Install CD March 2006 recut

- SCO OpenServer 6.0.0 Maintenance Pack 4 (MP4)

- SCO OpenServer 6.0.0 Maintenance Pack 4 Device Drivers. This will include the latest "ide" driver ver.7.1.4h and "nd" NIC drivers ver. 8.0.6g (Broadcom "bcme" version 10.4.5).

All above three are available on:
http://www.sco.com/support/update/download/product.php?pfid=1&prid=6

- HP "hpsas" HBA driver from PSP 7.811a (available from: http://www.hp.com/support )

Direct ftp URL link is:
ftp://ftp.hp.com/pub/softlib2/software1/pubsw-linux/p759431307/v56448/psp-7.811a-uw7_osr6.tar.Z
Installation
------------
Please Note:

The ML 350 G6 does not come with Legacy 1.44 MB floppy drive, therefore in order to load the additional "hpsas" HBA driver, you need to load the HBA via USB Floppy or SATA CD/DVD-ROM drive.

Very IMPORTANT Note:

In the case you have 2x Quad core CPU and before you install the OSr6, you need to carry out the following temporary changes in the BIOS.

Power On the ML 350-G6 and enter the BIOS (F9) and change the following setting:

System Options --> Processor Options --> Processor Core Disable, And change from "All Core Enabled" to "Half Core Enabled"

This will disable 2 cores on each physical Quad CPU giving a total of 4 core CPU (4 logical CPU).

If you fail to do that, OSR600 boot ISL will panic once the "hpsas" gets initialized.

To install:

- Boot the ML350 G6 server with March 2006 OSR6 Install CD and at the boot prompt, enter the following string:

[Boot] USE_XAPIC=Y
[Boot] PSM=atup
[Boot] b

USE_XAPIC=Y, this will prevent OSR6 ISL to panic when the HP "hpsas" HBA driver gets initialized. This is also related to the temporary BIOS changes.

PSM=atup, this will force OSr6 ISL to use ISL Mono-CPU mini kernel. Without this parameter, Osr6 ISL will use the default SMP-CPU mini kernel, thus causing the ISL to hang once the DVD-ROM drive gets initialized.

- Load the "hpsas" HBA via USB Floppy Drive or the HBA on a CD-ROM media ( TA 126675 ).

- Defer networking (will be done in POST INSTALLATION)

Installation then after is straight forward.
Post Installation
-----------------

- Boot the server and enter the BIOS and undo the changes for the Core CPU:

System Options --> Processor Options --> Processor Core Disable

And change from "Half Core Enabled" to "All Core Enabled"

- Boot OSr6 and at boot prompt, enter parameter USE_XAPIC=Y

- Install OpenServer 6 MP4. Before reboot, add this line into /etc/default/boot:

ACPI=Y

If you fail to do that, then at reboot, OSR6 will fail to boot.

- Optional: Update the "ide" driver to ver 7.1.4h from the OSR6 MP4 Driver CD.

- Install OSR6 nd package ver. 8.0.6g from the OSR6 MP4 Driver CD.

Configure the HP Embedded NC326i NIC
Please Note:

You will get two choices of drivers on the network configuration manager:

* Ethernet-HP NC326i Integrated Dual Port PCI Express Gigabit * Ethernet-Broadcom BCM571X NetXtreme Gigabit Ethernet(10.4.5)

It does not matter which one you choose, they both use the same "bcme" driver.

NOTE:     Troubleshooting
          ---------------

- It has been reported by some customers that with certain DVD-ROM drive models, at install or post install, the SATA DVD-ROM does not get recognised and an error message appear on the console when trying to access the DVD-ROM:

WARNING: atapi_protocal:ata_drvselect failed WARNING: CD-ROM Driver: HA 1 TC 0 LU0 - CHECK CONDITION

This is due to the fact that the "fd" driver reserves DMA which the DVD-ROM may need. This could cause the above warning messages.

To fix this, carry out ONE of the following workarounds (Only if you have issues accessing the DVD-ROM drive):

1- During ISL or Post Install, add this boot string line:

ATAPI_DMA_DISABLE=YES

The side effect of this workaround is, access to DVD-ROM drive will be slow.

You need to add this boot string in /stand/boot file to
make it permanent

2- During ISL or Post Install, disable the "fd" driver in the DCU.

3- Try plugging the SATA DVD-ROM Drive into another SATA port. In some reported cases, this has helped.

- After seeing the following message on boot up and hanging after memsize:

ACPI-1301 Error: Method Execution Failed
{\SB_.PMI0._STA] Node 0xC08A155L AE_AML_NO_RETURN_VALUE

The issue was resolved by upgrading the firmware of the server to the latest level which at the time was P62 10.1.2009 (DL380 G6) and entering the following boot parameter:

USE_XAPIC=Y
rather than ACPI=Y

See also

TA127504 - How to install SCO OpenServer 5.0.7 on the new HP Proliant ML350 G6?

TA127508 - How to install SCO UnixWare 7.1.4 on the new HP Proliant ML350 G6?

TA127541 - How to install SCO OpenServer 6.0.0 on the new HP Proliant ML370 G6?

From the Xinuos technical article database, record 127507. Reproduced with permission. The original is at www.sco.com/ta/127507, which is reachable but blocked from search engines.

Next step

Need this fixed rather than explained?

Tell us the release, what the system runs and what it is doing. We will reply by email with what we would do next.

  • You deal with the people who do the work
  • No obligation, and no upgrade required before we will help
  • We tell you plainly if something is not worth doing

Send an enquiry

We reply by email. If a server is down, say so in the first line. You can also write to help@scoexpert.com.